Energy configuration
Input calculation:
Enable or disable energy configuration options
.
Capacity configuration:
Due to usage of water temperature
inlet and outlet + water flow level, an
estimation of capacity can be checked
through the Operation information -
Energy data menu.
Due to the estimation, values may differ
from real ones.
Power meter 1 or 2:
•
The power meter does a real measuring of
the power consumption.
•
If the power meter is enabled, it is possible
to see the information collected through the
Operation information - Energy data menu.
•
If “power meter” is Deactivated the YUTAKI
software does an estimate consumption of
the system.
•
In case of using power meter 1 or 2 input
must be configured at the Inputs menu
“7.13.4.10 Inputs, Outputs and
).
Smart Function
1 / 3
2 / 3
3 / 3
Status:
Enable or disable smart function.
Trigger type:
•
Closed: Action when input is
closed
•
Open: Action when input is open
Start boiler:
Permission to use the boiler in case
that the system has been blocked
due to HP Block.
Start DHW Heater:
Permission to use the DHW heater
in case that the system has been
blocked due to HP Block.
Smart Action:
Check that Smart Act/SG1 is set in input 5
(see
section
“7.13.4.10 Inputs, Outputs and Sensors
•
HP Block:
Heat Pump is forbidden in any
condition (Space Heating, Cooling, DHW)
when signal is active.
•
HP Limited (A):
Limitation of power
consumption up to a limit of “x” amperes (to
be set up in Limitation of amperage).
•
SG Ready:
The SG Grid is awarded to
heat pump series. This control technology
integrates the system in a smart grid by using
two digital inputs establishing an unidirectional
connection. See Service Manual for detailed
information. It is necessary to configure an
input for SG2.
•
DHW Block:
DHW Operation is forbidden
when signal is active.
•
DHW only:
Heat pump operation for any
condition except DHW is forbidden when
signal is active. DHW operation is allowed
normally.
Limitation by ampere:
Configure the ampere consumption limitation.
Only visible when smart action is set as HP
Limited (A).
SG Heating offset:
To adjust Space Heating setting temperature
increase when SG ready is in Low price mode.
SG DHW offset:
To adjust DHW setting temperature increase
when SG ready is in Low price mode.
SG Cooling offset:
To adjust Space Cooling setting
temperature decrease when SG
ready is in Low price mode.