Hot water tank optional functions
Circuit Pump:
By using this output, user
can heat all the water inside DHW piping
system. Output must be configured at
the I/O and sensors menu. (see section
“8.13.3.11 Inputs, Outputs and Sensors
• Deactivated.
•
Demand: Enable DHW recirculation.
•
Anti Legionella: Allows DHW
recirculation while anti legionella is
active.
•
Timer: A timer can be programmed
in order to start or stop the water
recirculation.
Recirculation timer:
•
Frequency: Allows to select when
timer is applied (Everyday, weekend,
workday)
•
Starting Time: When the water pump
circulation starts.
•
Stopping Time: When the water
pump circulation stops.
•
Operation: In case of ON, means that
water pump is always ON between
“Starting Time” and “Stopping
Time”. In case it is set to Timer,
Recirculation pump is ON during
“ON Time” after being OFF during
“OFF Time” within Starting Time and
Stopping Time.
•
ON Time: On time period of
Recirculation pump.
•
OFF Time: Off time period of
Recirculation pump.
DHW Boost:
To force a one-time heating of the DHW tank up to
the temperature set as DHW Boost temperature.
This feature is useful to cover exceptional demand
of DHW.
•
Trigger type:
Push (favourite button), Open
(NC) or Closed (NO). Set input 6 for DHW
Boost (for trigger type open/closed). (see
“8.13.3.11 Inputs, Outputs and Sensors
•
Boost setting:
DHW temperature setting for the
Boost function.
Emergency Operation
Space Heating:
Enable or disable emergency operation
for space heating.
Only available in case “Heating source”
“8.13.3.7 Complementary Heating
contains “Electrical
heater or boiler” option.
Hot water tank:
Enable or disable emergency operation
for DHW. Only available when electrical
heater for DHW is enabled (by DSW).
Mode:
Selection of the emergency operation mode:
•
Manual:
Emergency operation is active when
is manually enabled (by DSW4 pin 4 ON). The
emergency mode uses the heater (space heating
or DHW) to provide the required heating.
•
Automatic:
Emergency mode operates when
there is an event of outdoor unit failure and
Demand ON of space heating (enabled) or DHW
(enabled).
YUTAKI CASCADE CONTROLLER
PMML0575 rev.1 - 09/2021
146