ENGLISH
Example 5
1- Main unit controller as unit configuration
2- Wireless intelligent thermostat for zone 1 (ATW-RTU-07) (Re Room thermostat)
3- Wireless intelligent thermostat for zone 2 (ATW-RTU-06) (Only Room thermostat)
Indoor unit
1
Living room Zone 1
Bedroom Zone 2
Order
FIRST
Type
Main
Unit + Circuits
Questions
Answers
Is this device attached to the unit?
YES
Is this device used as a Room Thermostat of a zone?
NO
How many circuits do you have?
2
Which are the heat emitters of circuit 2?
Underfloor heating
Do you have domestic hot water tank?
NO
Do you have swimming pool?
NO
Do you have boiler?
NO
Do you have electric backup heater?
NO
Which Thermostat do you have for Circuit 1?
Wireless
Which Thermostat do you have for Circuit 2?
Wireless
COMPLETED
?
N O T E
•
After finishing Configuration assistant proceed to wireless room thermostat binding procedure. (Refer to installation manual of room thermostat)
• If necessary, change Wireless Binding ID to the selected thermostat by using room thermostat menu in general options:
Description
Default Value
Range
Selected value
Wireless Binding ID (for C1)
1
1
2
1
Wireless Binding ID (for C2)
2
1
2
2
UNIT CONTROLLER
PMML0575 rev.1 - 09/2021
61