4.2.4 Space cooling (Necessary cooling kit)
Water outlet temperature (ºC)
Ambient temperature
(ºC(DB))
Refreshing floor
working area
Fan coil working
area
Continuous working range.
Maximum setting temperature.
Minimum setting temperature.
4.3 R410A HYDRAULIC WORKING RANGE
4.3.1 Hydraulic data
YUTAKI S
MODEL
4.0 HP
5.0 HP
6.0 HP
8.0 HP
10.0 HP
Minimum water flow rate (*1)
m
3
/h
1.0
1.1
1.2
2.0
2.2
Maximum water flow rate (*1)
m
3
/h
2.9
3.0
3.0
4.5
4.6
Minimum installation water volume (*2)
l
38
46
55
76
79
Minimum allowable water pressure
MPa
0.1
Maximum allowable water pressure
MPa
0.3
YUTAKI S COMBI
MODEL
4.0 HP
5.0 HP
6.0 HP
Minimum water flow rate (*1)
m
3
/h
1.0
1.1
1.2
Maximum water flow rate (*1)
m
3
/h
2.7
2.8
2.8
Minimum installation water volume (*2)
l
38
46
55
Minimum allowable water pressure
MPa
0.1
Maximum allowable water pressure
MPa
0.3
WORKING RANGE
PMML0575 rev.1 - 09/2021