Management module on page 4-61
section.
7
.
Remove all cables for the failed management module.
8
.
Release the blue lock tab and pull the lever, as shown below.
9
.
Holding the management module, carefully slide out the management
module from the chassis and place it on an anti-static mat.
Figure 5-130 Removing a management module
Installing a management module
1
.
Put on an anti-static wrist strap.
2
.
Reverse the removal procedure to install the management module.
3
.
Verify that the Power LED and MSR LED are blinking in green after Power
LED blinked in green.
4
.
Connect the LAN cable to the master management module and start the
Web console.
5
.
Synchronize the internal LAN between the primary management module
and the target one.
Select Resources tab on the web console and select Modules > All
Modules > Management Modules.
6
.
Click Action and select Sync Internal LAN.
7
.
The confirmation dialog box appears. Click OK. Synchronizing internal
address will start.
Replacing parts
5-101
Hitachi Compute Blade 500 Series System Service Manual
Summary of Contents for CB 520A A1
Page 26: ...xxvi Preface Hitachi Compute Blade 500 Series System Service Manual ...
Page 152: ...4 64 Common process for replacement Hitachi Compute Blade 500 Series System Service Manual ...
Page 294: ...6 12 Identifying RAID rebuild status Hitachi Compute Blade 500 Series System Service Manual ...
Page 432: ...9 16 Updating firmware Hitachi Compute Blade 500 Series System Service Manual ...
Page 439: ...Change LOM configuration 10 7 Hitachi Compute Blade 500 Series System Service Manual ...
Page 442: ...10 10 Change LOM configuration Hitachi Compute Blade 500 Series System Service Manual ...
Page 450: ...10 18 Change LOM configuration Hitachi Compute Blade 500 Series System Service Manual ...
Page 464: ...11 14 Troubleshooting Hitachi Compute Blade 500 Series System Service Manual ...
Page 465: ...Hitachi Compute Blade 500 Series System Service Manual ...