5
.
Wait until rebuild progress state becomes 100%. or indicates a hyphen
6
.
Enter
hrncli -ldpdprog
in the root@localhost:~/desktop window.
Confirm whether the rebuilding finished normally.
When the rebuilding finished normally, Optimal is indicated in State
column of the LD No. See the following examples.
[Example: Normal end of rebuilding]
[Example: Abnormal end of rebuilding]
Identifying RAID rebuild status
6-9
Hitachi Compute Blade 500 Series System Service Manual