No.
Server model
# of CNA
1
# of CTRL
2
Controller #
#2, #3 for Mezz #2
#4, #5 for Mezz #4
Notes:
1
.
The # of CNA indicates the total number of installed Emulex 10Gb CNA
mezzanine card and LAN mezzanine card.
2
.
Confirm the indicated number of controllers in Controller Selection Menu window
is equal to the # of Controller indicated in this table for the replaced server
configuration.
3
.
The controller #0 for is assigned to LOM for CB 520H B1 (GGAGC0Bn- with
LOM).
4
.
The controller #0 and #1 are assigned to LOMs for CB 540A B1 (GGAGD0Bn-
with LOM).
Note: The Personality for Emulex 10Gb LAN mezzanine card and LOM is
fixed to NIC by default and cannot change.
7
.
Port Selection menu window is displayed. Select the port#0, and then
press Enter key.
8
.
MultiChannel Configuration window is displayed. Confirm and record
the configuration of PXE Boot Support.
9
.
If PXE Boot Support is Enabled, confirm and record Bandwidth and
LPVID.
Configuring Emulex mezzanine card
7-59
Hitachi Compute Blade 500 Series System Service Manual
Summary of Contents for CB 520A A1
Page 26: ...xxvi Preface Hitachi Compute Blade 500 Series System Service Manual ...
Page 152: ...4 64 Common process for replacement Hitachi Compute Blade 500 Series System Service Manual ...
Page 294: ...6 12 Identifying RAID rebuild status Hitachi Compute Blade 500 Series System Service Manual ...
Page 432: ...9 16 Updating firmware Hitachi Compute Blade 500 Series System Service Manual ...
Page 439: ...Change LOM configuration 10 7 Hitachi Compute Blade 500 Series System Service Manual ...
Page 442: ...10 10 Change LOM configuration Hitachi Compute Blade 500 Series System Service Manual ...
Page 450: ...10 18 Change LOM configuration Hitachi Compute Blade 500 Series System Service Manual ...
Page 464: ...11 14 Troubleshooting Hitachi Compute Blade 500 Series System Service Manual ...
Page 465: ...Hitachi Compute Blade 500 Series System Service Manual ...