No.
Name
State
Description
4
Reset switch (RST)
-
Press and hold for five seconds to reset the
LAN switch module.
5
Power LED (PWR)
Green-On
Powered-on, normal operation.
6
Status1 LED (ST1)
Green-On
Normal operation.
Green-Blink Power-on diagnosis or software activation.
Red-Blink
Fault. Maximum temperature limit exceeded
or other warning.
Red-On
Alarm.
7
Identify LED (LOCID)
Blue-On
The switch module is identified.
1/10Gb LAN switch module
Figure 1-44 1/10Gb LAN switch module
Table 1-36 LEDs and connectors on 1/10Gb LAN switch module
No.
Name
State
Description
1
LAN ports 1 to 4
Green-On
Link is established
Green-Blink Link activity. Port is sending or receiving data.
Amber-On
Link failed.
2
10GBASE-R slots
-
Slots for 10GBASE-LR or 10GBASE-SR
transceiver: Each slot has a link LED on the
upper right and a TX/RX LED on the lower
right.
3
Memory Card slot (MC) -
Slot for SD memory card.
4
Access LED (ACC)
Green-On
The SD memory card is accessed
5
Reset switch (RST)
-
Press and hold it for about five seconds or
more, reset the module.
6
TX/RX LED for XFP
Green-On
A link is established on 10BASE-R and the
port is sending or receiving data.
Off
The port is neither sending nor receiving data.
7
LINK LED for XFP
Green-On
A link is established on 10BASE-R.
Introduction
1-33
Hitachi Compute Blade 500 Series System Service Manual
Summary of Contents for CB 520A A1
Page 26: ...xxvi Preface Hitachi Compute Blade 500 Series System Service Manual ...
Page 152: ...4 64 Common process for replacement Hitachi Compute Blade 500 Series System Service Manual ...
Page 294: ...6 12 Identifying RAID rebuild status Hitachi Compute Blade 500 Series System Service Manual ...
Page 432: ...9 16 Updating firmware Hitachi Compute Blade 500 Series System Service Manual ...
Page 439: ...Change LOM configuration 10 7 Hitachi Compute Blade 500 Series System Service Manual ...
Page 442: ...10 10 Change LOM configuration Hitachi Compute Blade 500 Series System Service Manual ...
Page 450: ...10 18 Change LOM configuration Hitachi Compute Blade 500 Series System Service Manual ...
Page 464: ...11 14 Troubleshooting Hitachi Compute Blade 500 Series System Service Manual ...
Page 465: ...Hitachi Compute Blade 500 Series System Service Manual ...