LPAR manager does not check if the entered value is used for another LPAR
manager system. You can change the LP ID only when all LPARs are
deactivated.
How to set the ServerConductor/Blade Server Manager (BSM) IP
Address
Place the cursor on the BSM IP Address and press Enter to display a sub-
screen. Enter the new System Manager IP Address on the sub-screen and
press Enter.
Note:
•
Operation with F10: Update System Config is not required to reflect a
setting change. It may take about 10 seconds to reflect a setting change.
How to set the ServerConductor/Blade Server Manager (BSM) Alert
Port
Place the cursor on the BSM Alert Port and press Enter to display a sub-
screen. Enter the new BSM Alert Port Number in the sub-screen and press
Enter.
Note:
•
Operation with F10: Update System Config is not required to reflect a
setting change. It may take about 10 seconds to reflect a setting change.
How to set the VNIC System No.
Place the cursor on the VNIC System No. and press Enter to display a sub-
screen. Enter the new virtual NIC Setting Number on the sub-screen and
press Enter. The initial setting of the VNIC System No. is 0. Set the new
value except 0 at the first LPAR manager boot. Otherwise, the LPAR manager
system will not boot.
You can change the VNIC System No. only when all LPARs are deactivated.
LPAR manager does not check if the entered value is used for another LPAR
manager system.
Note:
•
A VNIC System No. is used for creating a unique MAC address to a Logical
NIC. Thus, set a unique value to all LPAR manager system such as
Compute Blade Series.
•
Do not change the VNIC system No., otherwise the following phenomena
might occur.
– The MAC address of the Logical NIC assigned to the guest OS on LPAR
manager will change.
– When reusing VNIC System No. which was used on other LPAR
manager, MAC address of Logical NIC might overlap with others.