No.
Item
Description
Default
Value
Supported
LPAR
manager
Version
(8)
Current
RTC
Displays in decimal the difference between
the LPAR RTC time and the LP system time.
0
01-0X~
Init RTC
Displays, in decimal, the difference value
between the LPAR RTC time saved in the
configuration information and the LPAR
manager system time. This value is
determined immediately after the LPAR
manager system startup and is not
changed during LPAR manager system
operation.
The initial RTC value is displayed when RTC
Last Modified has been displayed in the
display time selection.
(9)
Date and
Time
Displays the LPAR manager System date
and time.
The system equipment time is applied as
the default at LPAR manager boot.
-
01-0X~
(10) Time Zone
Displays and sets which time zone the
LPAR manager System date and time
belongs to.
If you change the value, LPAR manager
time will not be changed because this item
only shows the difference between LPAR
manager system time and GMT.
You can specify it on 1-hour basis, and the
minimum value is -12 hours and the
maximum value is +12 or +14 hours. LPAR
manager system time zone will be set in
the SEL time zone when an LPAR is
created.
+ 0:00
01-0X~
(11) Adjust
LPAR Time
Adjusts the RTC and SEL time of LPARs to
the LPAR manager system time or UTC
time.
In this case, the following times of the
LPAR to be changed are also cleared: Last
Activate RTC time, last Deactivate RTC
time, and last RTC update RTC time.
[LPAR manager firmware version 01-6X or
later]
LP System Time: Synchronizes RTC time
and SEL time of an LPAR with LPAR
manager system time.
Specified Zone: In a specified time zone,
synchronizes RTC time and SEL time of an
LPAR with LPAR manager system time.
UTC: Synchronizes RTC time and SEL time
of an LPAR with UTC time.
-
01-0X~
Operation by LPAR manager Screen
7-85
Hitachi Compute Blade 500 Series Logical partitioning manager User's Guide