Message Content
LP failed to get the firmware version on a NIC device.
What to do
Reboot the LPAR manager. If this LP system log is collected after
rebooting, contact the reseller from which you purchased this
equipment or consult maintenance personnel.
Message Content
LP failed to have SR-IOV device enabled.
Explanation
Detects different SR-IOV settings (enable/disable) for two ports of
the same controller of PCI device.
What to do
Check the SR-IOV settings of PCI device, or confirm that
"Personality" is set to NIC mode.
See the Hitachi Compute Blade Emulex Adapter User's Guide for
Hardware for setting it.
However, it cannot be changed in LP mode. If necessary, change
it in Basic mode.
Message Content
LP Loader could not update LP Serial Number in OEM FRU.
Explanation
Updating the FRU in LPAR manager boot failed, when the N+M
was performed.
What to do
There is a possibility that the BMC error occurred or FRU data is
damaged. Contact the reseller from which you purchased this
equipment or consult maintenance personnel.
Message Content
LP-LFW detected internal error.
Explanation
LPAR manager logical firmware detected an internal error.
What to do
Contact your reseller or maintenance personnel.
Message Content
LPAR damage occurred.
Explanation
An LPAR manager fault (LPAR fault) occurred.
What to do
Contact the reseller from which you purchased this equipment or
consult maintenance personnel.
Message Content
LPAR damage occurred. (due to H/W error)
Explanation
An LPAR manager fault (LPAR fault) resulting from a hardware
fault occurred.
What to do
Contact the reseller from which you purchased this equipment or
consult maintenance personnel.
Message Content
Network configuration error for Shared FC at expansion
card.
Explanation
A shared FC interface fault occurred.
9-34
Messages
Hitachi Compute Blade 500 Series Logical partitioning manager User's Guide