ID
Message
Operation for which an audit log is
collected
01003177
"Failed to set the synchronization
method of LPAR manager system time.
Value:
xxx
"
When the LPAR manager screen is used to
request change of the time synchronization
with NTP server (TimeSync) and the request
fails
01003178
"Requested to set NTP server1 to
synchronize the LPAR manager system
time. Accept:
xxx
Value:
xxx
"
When HvmSh and so on is used to request
setting change of NTP Server1 and the
request is accepted
0100317A
"Set the NTP server1 to synchronize
LPAR manager system time. Value:
xxx
"
When the LPAR manager screen is used to
request setting change of NTP Server1 and
the request succeeds
0100317B
"Failed to set the NTP server1 to
synchronize LPAR manager system time.
Value:
xxx
"
When the LPAR manager screen is used to
request setting change of NTP Server1 and
the request fails
0100317C
"Requested to set NTP server2 to
synchronize LPAR manager system time.
Accept:
xxx
Value:
xxx
"
When HvmSh and so on is used to request
setting change of NTP Server2 and the
request is accepted
0100317E
"Set NTP server2 to synchronize LPAR
manager system time. Value:
xxx
"
When the LPAR manager screen is used to
request setting change of NTP Server2 and
the request succeeds
0100317F
"Failed to set NTP server2 to
synchronize LPAR manager system time.
Value:
xxx
"
When the LPAR manager screen is used to
request setting change of NTP Server2 and
the request fails
01003180
"Requested to import the NTP settings
of the LPAR manager. Accept:
xxx
From:
xxx
"
When HvmSh and so on is used to request
importing of NTP setting (Import Config) and
the request is accepted
01003182
"Imported the NTP settings of the LPAR
manager. From:
xxx
"
When the LPAR manager screen is used to
request importing of NTP setting (Import
Config) and the request succeeds
01003183
"Failed to import the NTP settings of
the LPAR manager. From:
xxx
"
When the LPAR manager screen is used to
request importing of NTP setting (Import
Config) and the request fails
01003184
"Initialized all options of the FC HBA
driver. LPAR
xxx
Slot#:
xxx
Port#:
xxx
"
When HvmSh and so on is used to request
clearing of the options of the FC HBA driver
of the logical EFI and the request
immediately succeeds
01003186
"Enabled or disabled the BootFunction
of the FC HBA driver option. LPAR
xxx
Slot#:
xxx
Port#:
xxx
Value:
xxx
"
When HvmSh and so on is used to request
change of the bootfunc option of the FC HBA
driver of the logical EFI and the request
immediately succeeds
01003188
"Set the ConnectionType of the FC HBA
driver option. LPAR
xxx
Slot#:
xxx
Port#:
xxx
Value:
xxx
"
When HvmSh and so on is used to request
change of the ConnectionType option of the
FC HBA driver of the logical EFI and the
request immediately succeeds
0100318A
"Enabled or disabled the
MultiplePortID of the FC HBA driver
When HvmSh and so on is used to request
change of the MultiplePortID option of the FC
HBA driver of the logical EFI and the request
immediately succeeds
9-78
Messages
Hitachi Compute Blade 500 Series Logical partitioning manager User's Guide