Item
Support (version)
VLAN
11, 15, 20
Undef
-
Port VLAN
(Untagged)
17
Y (01-9X or later)
(Only one VLAN can be
set to one VF port.)
Tagged VLAN
Y (01-9X or later)
(Only [All] can be set.)
Inter LPAR communication
12, 13
Y (01-9X or later)
LPAR manager
functions
User interface
HVM Navigator
Y (01-9X or later)
LPAR manager
screen
Y (01-9X or later)
HvmSh
Y (01-9X or later)
LPAR migration
Shutdown
Y (01-9X or later)
Concurrent
maintenance
-
Force Recovery
14
Y (01-9X or later)
Middleware
HCSM
Y (01-9X or later)
(Display only)
SC/BSM
-
SC/DPM
-
Server installation and monitoring tool
(SIMT) log monitor
Y (01-9X or later)
Linux high
reliability options
Linux Tough Dump
Y (01-9X or later)
HA Network Driver
for Linux
-
HA Logger Kit for
Linux
Y (01-9X or later)
Notes:
1
.
Emulex 10 Gb NIC has multiple ports per controller. Set the same value of SR-IOV
to ports in the controller: Enable or Disable.
2
.
Emulex 10Gb NIC of different types of firmware cannot be mounted in a server
blade.
3
.
For details about combinations of firmware versions and drivers, see the Hitachi
Compute Blade Emulex Adapter User's Guide for Driver.
4
.
When a guest OS, to which VF NIC is assigned, is rebooted, the following messages
may appear in /var/log/messages and in the system event log if SIMT log monitor is
running. They do not affect the guest OS operation.
[/var/log/messages]
be2net 0000:XX:XX.X: Could not use PCIe error reporting
XX:XX.X: Bus: Dev. Func
[System event log]
A-20
Setting Item Catalogue