Do not leave a slot open for a long time. Leaving it open can cause the
overheat problem for other components.
Installing a full-wide server blade
Note: To change configuration from half-wide server blade to full-wide server
blade, remove a shelf from the server chassis. Refer to the
in the server chassis on page 5-129
section.
1
.
Put on an anti-static wrist strap.
2
.
Reverse the removal procedure.
3
.
When you install a CB 520X B1/B2/B3 in SMP configuration, install the 2-
blade SMP connection board or 4-blade SMP connection board. See
Installing an SMP connection board on page 5-9
section.
4
.
Turn on LID LED for identifying the target blade. See
section.
5
.
If you need to update the BMC and/or EFI firmware, consult with Hitachi
Data Systems Customer Support team.
6
.
Restore the Blade configuration data (FRU/ BMC configuration/ EFI
configuration) from the automatic back up field in server chassis. See
Backup/restore procedure on page 4-30
7
.
BMC will restart. Wait for about 10 minutes.
8
.
Select Alerts tab and select All Logs > System Event Log, and then
click Refresh to identify the latest information.
9
.
Confirm the Server blade: BMC initialization complete message.
If this massage was displayed, go to next step.
Figure 5-4 Confirming system log
10
.
Turn on LID LED for identifying the target blade again. See
(LID) on/off procedure on page 4-7
11
.
Execute the CBTP and check the replaced server blade. See
section.
12
.
Turn off the maintenance mode from web console. See
section.
Replacing parts
5-7
Hitachi Compute Blade 500 Series System Service Manual
Summary of Contents for CB 520A A1
Page 26: ...xxvi Preface Hitachi Compute Blade 500 Series System Service Manual ...
Page 152: ...4 64 Common process for replacement Hitachi Compute Blade 500 Series System Service Manual ...
Page 294: ...6 12 Identifying RAID rebuild status Hitachi Compute Blade 500 Series System Service Manual ...
Page 432: ...9 16 Updating firmware Hitachi Compute Blade 500 Series System Service Manual ...
Page 439: ...Change LOM configuration 10 7 Hitachi Compute Blade 500 Series System Service Manual ...
Page 442: ...10 10 Change LOM configuration Hitachi Compute Blade 500 Series System Service Manual ...
Page 450: ...10 18 Change LOM configuration Hitachi Compute Blade 500 Series System Service Manual ...
Page 464: ...11 14 Troubleshooting Hitachi Compute Blade 500 Series System Service Manual ...
Page 465: ...Hitachi Compute Blade 500 Series System Service Manual ...