Do not leave a slot open for a long time. Leaving it open can cause the
overheat problem for other components.
Installing a PCI expansion blade into server chassis
Note: To change configuration from half-wide server blade to PCI expansion
blade, remove the shelf from the server chassis. Refer to the
shelf in the server chassis on page 5-129
section.
1
.
Put on an anti-static wrist strap.
2
.
Reverse the removal procedure.
3
.
Turn on LID LED for identifying the target blade. See
4
.
If you need to update the BMC and/or EFI firmware, consult with Hitachi
Data Systems Customer Support team.
5
.
Restore the Blade configuration data (FRU/ BMC configuration/ EFI
configuration) from the automatic back up field in server chassis. See
Backup/restore procedure on page 4-30
section.
6
.
BMC will restart. Wait for about 10 minutes.
7
.
Select Alerts tab and select All Logs > System Event Log, and then
click Refresh to identify the latest information.
8
.
Confirm the Server blade: BMC initialization complete message.
If this massage was indicated, go to next step.
Figure 5-12 Confirming system log
9
.
Turn on LID LED for identifying the target blade again.
See
Identify LED (LID) on/off procedure on page 4-7
section.
10
.
Execute the CBTP and check the replaced PCI expansion blade.
See
Diagnostic procedure overview on page 8-2
11
.
Turn off the maintenance mode from web console.
See
Maintenance mode on/off procedure on page 4-10
section.
12
.
Restart BMC when you installed a new server blade. See
5-16
Replacing parts
Hitachi Compute Blade 500 Series System Service Manual
Summary of Contents for CB 520A A1
Page 26: ...xxvi Preface Hitachi Compute Blade 500 Series System Service Manual ...
Page 152: ...4 64 Common process for replacement Hitachi Compute Blade 500 Series System Service Manual ...
Page 294: ...6 12 Identifying RAID rebuild status Hitachi Compute Blade 500 Series System Service Manual ...
Page 432: ...9 16 Updating firmware Hitachi Compute Blade 500 Series System Service Manual ...
Page 439: ...Change LOM configuration 10 7 Hitachi Compute Blade 500 Series System Service Manual ...
Page 442: ...10 10 Change LOM configuration Hitachi Compute Blade 500 Series System Service Manual ...
Page 450: ...10 18 Change LOM configuration Hitachi Compute Blade 500 Series System Service Manual ...
Page 464: ...11 14 Troubleshooting Hitachi Compute Blade 500 Series System Service Manual ...
Page 465: ...Hitachi Compute Blade 500 Series System Service Manual ...