To change the OS operation mode to normal mode, see 5.14.4 Changing maintenance mode to normal mode.
(3) Restoring data in configuration No. 2
The following describes the procedure for restoring backup data from the maintenance PC connected to the unit.
(a) Preparation
•
The maintenance PC shall have the capability of executing the
scp
command. (Tera Term has the scp capability.)
•
Stop the unit, and then connect it to the maintenance PC by using an Ethernet cable.
If necessary, disconnect other devices from the unit.
•
Change the OS operation mode of the unit from normal mode to maintenance mode.
•
Use terminal emulation software for remote connection to the unit from the maintenance PC, and then log in to the
unit by using SSH.
You must log in as a user who can run the
sudo
command.
•
The time required to restore data from a backed up file is approximately 30 seconds per GB. If files are to be
verified, additional time (approximately 30 seconds) is required. More time might be required depending on the
transfer rate of the external media. In addition, the time for transferring backup files to the unit is required.
(b) Operation procedure
Use the remote operation terminal to remotely log in to the unit in which the backup data is to be restored, and then
run the restoration command. Then, send backup data from the maintenance PC to the unit by using the
scp
operation
terminal.
Figure 5‒23: Flow of restoration procedure in configuration No. 2
1. Check the communication between the maintenance PC and the unit by using the remote operation terminal.
Run the
ping
command to confirm that the maintenance PC can communicate with the unit.
5. Configuring Software Environment
88
Summary of Contents for CE50-10
Page 1: ...Hitachi Industrial Edge Computer CE50 10 Instruction Manual CC 65 0171 ...
Page 10: ......
Page 23: ...Figure 1 6 Attaching mounting brackets 4 1 Installing the CE50 10 7 ...
Page 26: ......
Page 38: ......
Page 42: ...4 2 5 Connection diagram Figure 4 2 Connection diagram 4 External Contact Functions 26 ...
Page 44: ......
Page 87: ... sudo etc init d netfilter persistent save 5 Configuring Software Environment 71 ...
Page 117: ...version information 13 Log out from the unit exit 5 Configuring Software Environment 101 ...
Page 148: ......
Page 149: ...7 Maintaining the CE50 10 This chapter describes maintenance of the CE50 10 133 ...
Page 157: ...8 Troubleshooting This chapter describes troubleshooting of the CE50 10 141 ...
Page 162: ...8 1 14 Cannot turn off the power to the unit Please contact us 8 Troubleshooting 146 ...