4.3 DI (EXT)
4.3.1 Signal name
DI_01, DI_02, DI_03, DI_04, DI_GND
4.3.2 Description
General-purpose contact input signals.
Meanings of the signals can be defined for each system by using a user program.
4.3.3 Specifications
Table 4‒5: DI contact specifications
I/O
Item
Specifications
Input specifications
Input method
Photocoupler contact
Rated input voltage
24 V DC (external power supply)
Rated input current
5 mA/point
Response time
10 ms or less (per contact)
Dielectric strength
250 V AC, 1 minute
4.3.4 Terminal number
Table 4‒6: DI terminal number
Signal
Terminal number
DI_01
11
DI_02
12
DI_03
24
DI_04
25
DI_GND
10, 13, 23
4.3.5 Connection diagram
Figure 4‒3: Connection diagram
4. External Contact Functions
27
Summary of Contents for CE50-10
Page 1: ...Hitachi Industrial Edge Computer CE50 10 Instruction Manual CC 65 0171 ...
Page 10: ......
Page 23: ...Figure 1 6 Attaching mounting brackets 4 1 Installing the CE50 10 7 ...
Page 26: ......
Page 38: ......
Page 42: ...4 2 5 Connection diagram Figure 4 2 Connection diagram 4 External Contact Functions 26 ...
Page 44: ......
Page 87: ... sudo etc init d netfilter persistent save 5 Configuring Software Environment 71 ...
Page 117: ...version information 13 Log out from the unit exit 5 Configuring Software Environment 101 ...
Page 148: ......
Page 149: ...7 Maintaining the CE50 10 This chapter describes maintenance of the CE50 10 133 ...
Page 157: ...8 Troubleshooting This chapter describes troubleshooting of the CE50 10 141 ...
Page 162: ...8 1 14 Cannot turn off the power to the unit Please contact us 8 Troubleshooting 146 ...