Run the
showecmode
command to check the next OS operation mode. Confirm that the display for
Next
has
changed to
Maintenance
mode
(see the
bold underlined part
).
$ sudo showecmode
Current : Normal mode
Next :
Maintenance mode
$
5. Stop the unit.
Run the
shutdown
command to stop the unit, and then turn off the power.
$ sudo shutdown -h 0
6. Unplug or connect the LAN cable.
Unplug the LAN cables to disconnect the unit from the remainder of the system. To connect the unit and the
maintenance PC, use the LAN cable to directly connect them.
7. Start the unit.
Turn on the power to the unit.
8. Log in to the unit.
login: edgeadm
Password: *******
9. Check the current OS operation mode.
Run the
showecmode
command to check the current OS operation mode.
Confirm that
Maintenance mode
is displayed for both
Current
and
Next
(see the
bold underlined
parts
).
$ sudo showecmode
Current :
Maintenance mode
Next :
Maintenance mode
$
5.14.4 Changing maintenance mode to normal mode
1. Log in to the unit.
login: edgeadm
Password: *******
2. Check the current OS operation mode.
Run the
showecmode
command to check the current OS operation mode. Confirm that
Maintenance
mode
is
displayed for both
Current
and
Next
(see the
bold underlined parts
).
$ sudo showecmode
Current :
Maintenance mode
Next :
Maintenance mode
$
3. Specify normal mode for the next OS operation mode.
Run the
ecmodeset
command to specify
Normal
mode
for the next startup of the OS (see the
bold underlined
parts
).
$ sudo ecmodeset -disable
Set next boot :
Normal mode
$
4. Check the setting of the next OS operation mode.
Run the
showecmode
command to check the next OS operation mode. Confirm that the display for
Next
has
changed to
Normal
mode
(see the
bold underlined parts
).
$ sudo showecmode
Current : Maintenance mode
Next :
Normal mode
$
5. Configuring Software Environment
74
Summary of Contents for CE50-10
Page 1: ...Hitachi Industrial Edge Computer CE50 10 Instruction Manual CC 65 0171 ...
Page 10: ......
Page 23: ...Figure 1 6 Attaching mounting brackets 4 1 Installing the CE50 10 7 ...
Page 26: ......
Page 38: ......
Page 42: ...4 2 5 Connection diagram Figure 4 2 Connection diagram 4 External Contact Functions 26 ...
Page 44: ......
Page 87: ... sudo etc init d netfilter persistent save 5 Configuring Software Environment 71 ...
Page 117: ...version information 13 Log out from the unit exit 5 Configuring Software Environment 101 ...
Page 148: ......
Page 149: ...7 Maintaining the CE50 10 This chapter describes maintenance of the CE50 10 133 ...
Page 157: ...8 Troubleshooting This chapter describes troubleshooting of the CE50 10 141 ...
Page 162: ...8 1 14 Cannot turn off the power to the unit Please contact us 8 Troubleshooting 146 ...