--- 14 ---
9-7. Insulation Tests
On completion of disassembly and repair, measure the insulation resistance and conduct dielectric strength test.
9-8. No-Load Current Values
After 30 minutes of no-load operation, current values should be as follows:
110 V
115 V
120 V
127 V
Less than 1.8 A
220 V ......... Less than 1.0 A
230 V ......... Less than 0.9 A
240 V ......... Less than 0.9 A