background image

I N S T R U C T I O N S   T O   U S E R :

This equipment complies with the requirements of FCC (Federal Communication

Commission) Class A equipments provided that the following conditions are met.

(1) Video signal cables:

Double shielded 

 cables (so called FCC shield cable) should be used and

the outer shield should be connected to the ground.

Or, if normal coaxial cables

are used, the cables should be enclosed in metal pipes or similar way to reduce

the interference noise radiation.

(2) Power cord:

Shielded power cord should be used.

The outer shield should be connected to the

ground.

 Video inputs:

The input signal amplitude must not exceed the specified level.

G E N E R A L

The 

 is an ultra high resolution color display designed for 

engineering and workstation use:

 

k e y   f e a t u r e s   a r e :

 Ultra-high resolution up to 1280 dots X 1024 lines

 Full square and flatter face plate screen.

 Sharp focus by in-line gun high resolution CDT 21 inch 

 with a 0.31 mm dot

pitch matrix.

* Higher legibility at corners with dynamic focusing system.

* Bright color picture with low distortion due to the use of an efficient high

performance deflection yoke.

* Compact chassis and low power consumption with switching power supply and self

converging system.

 Ergonomically designed cabinet with tilt and swivel stand.

Summary of Contents for CM2186A

Page 1: ...RATING GUIDE For future reference record the model and serial number of your display monitor Model No Serial No The numbers are located on the rear of the set Read the instruction inside carefully Keep this manual for future reference ...

Page 2: ...dio frequency energy and if not installed and used in accordance with the instructions manual may cause interference to radio communications It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operati...

Page 3: ...ted to the ground 3 Video inputs The input signal amplitude must not exceed the specified level G E N E R A L The CM2186A is an ultra high resolution color display designed for CAD CAM CAE engineering and workstation use CM2186A s k e y f e a t u r e s a r e Ultra high resolution up to 1280 dots X 1024 lines Full square and flatter face plate screen Sharp focus by in line gun high resolution CDT 2...

Page 4: ...isplay is equipped with a three wire type plug This plug will only fit into a grounding type power receptacle This is a safety feature do not defeat the safety purpose of the grounding type plug 2 If the power cord or plug is damaged or frayed replace it 3 Do not overload wall receptacles or extension cords as this can result in fire or electric shock W A R N I N G T O P R E V E N T S H O C K O R ...

Page 5: ... unit to vibrations dust or corrosive gases K E E P I N A W E L L V E N T I L A T E D P L A C E Ventilation holes are provided on the cabinet to prevent the temperature from rising DO NOT cover the unit ollplace anything on top of the unit A V O I D H E A T Avoid placing the unit in direct sunshine or near heating appliance B E C A R E F U L O F M A G N E T I C F I E L D S Do not place a magnet sp...

Page 6: ... N T R O L S Adjust the picture contrast and brightness on the screen DEGAUSSING S W I T C H This display is equipped with an automatic degaussing circuit This circuit operates when power is switched on If the display is turned horizontally and picture color becomes un uniform push this switch to get fine color uniformity Picture become still after some ten seconds h ...

Page 7: ...AC INLET G B R I o 0 o o I I R G B SIGNAL INPUT SYNC SIGNAL INPUT Fig 2 Rear view ...

Page 8: ...I O N Connect R G B signal BNC connectors to the signal input Vhen one display is used the termination S1 must be switched to 75 DtM side see Fig 3 lhen more than one display are used at the sane tine loop through state see Fig 4 for connecting cabies For loop through cpnnection T type connectors option have to be used and termination S P DUSt be switched to High impedance side other than the last...

Page 9: ... HI W Sync width 0 047 IDS 3 II B Back porch 0 547 mS 35 HI D Display time 1 6 0 2 6 mS 1024 H 6 3 9 kHz 2 3 6 uS 11 92 d3 Sync on Green mode Video C B I D I Green with Sync H V Composite Sync mode Video R G B S y n c lUUUL e e F W B c l T v m mm Two types of Sync mode H V Composite Sync mode and Composite Sync on Green mode are automatically Selectable The priority is H V Composite Sync 9 ...

Page 10: ...ocation or the picture size on the screen needs to be readjusted by qualified personnel If necessary refer adjustment to your dealer R E A D J U S T M E N T P R O C E D U R E 1 Remove the lid for adjustment Refer to Fig 5 2 Refer to the table 12 To display appropriate picture on screen adjust the H PHASE and the H SIZE with plastic trimmer 3 If necessary adjust the other VI shown in the table 4 Fo...

Page 11: ... SIDE VIEW LID ADJUSTMENTVR ADJUSTMENT DRIVER Fig 5 Removal of lid readjustment method 11 ...

Page 12: ...djustment shown below by qualified personnel is required when signals other than the recommended signal are received Refer servicing to your dealer I Picture deviated to Picture deviated Picture deviated ...

Page 13: ...sind die Bauirt der Bildtihre und die der Hochspannungserzeugung und stabilisierung dienencen Uaugruppen des Chassis Auflaae aem 10 RoV Die Ger6te sind mit dem Kennzeichen HH 918916 und mit folgendem Hinweis zu versehen Die in diesem GerOt entstehende Rdntgenstrahlung ist ausreichend abgeschirmt Die Beschleunigungsspannung betr8gt maximal 31 OkV I BESCHEINIGUNG DES HERSTELLERS I IMPORTEUIZS 1 Hier...

Page 14: ...S SET OUT IN THE RADIO INTERFERJZNCE REGULATIONS OF THE CANADIAN DEPARTMENT OF COMMUNICATIONS AVIS LE PaSENT APPAREIL NUMIhIQUE N lhET PAS DE BRUITS RADIOtiLECTRIQUES DfiPASSANTLES LIMITES APPLICABLES AUXAPPAREILSNUM IQUESDE CLASSEA PR RITE DAN LER GLE NTSUR LE BROUILLAGE RADIOtiLECTRIQUE tiDICTl PAR LE MINIST RE DES COMMUNICATIONS DUCANADA ...

Page 15: ...75 fi terminated SYNC SIGNAL 00 3 Vpp negative Composite sync on Green or Composite sync lTL level Negative SCANNING FREQUENCY Horizontal 64 kHz RECOMMENDED Vertical 60 Hz HAXIMUH RESOLUTION 1280 dots H X 1024 lines V DISPLAY SIZE u 350 mm wide X 280 mm high with recommended timing MISCONVERGENCE 0 3 mm max center 0 5 mm max corners 0 3 mm typ c mf s contrast brightness degaussing SW DIMENSIONS 48...

Page 16: ......

Reviews: