5 USER GUIDE
5-11
5.3.2 Setting
Single-port
Transceiver
Single-port transceivers have an SQE switch. Set the SQE switch according to the destination
unit to which the transceiver connects.
Table 5-3 SQE Switch Settings
Connected device
CMU controller
Multi-port transceiver
Repeater
SQE switch setting
ON
OFF
OFF
For the single transceivers HLT-200 and HLT-200TB, the SQE switch is contained in the case.
When changing the setting, open the case to do the work. The switch is set to ON by turning it
to the “SQE” side of silk printing on the board.
SQE
OFF ON