Table 4-7 Controller properties submenu 2 items
Menu items
Description
Setting/display value
Battery Backup
Cache backup module mount
status
None/Present (See
Module: BBU setting submenu on
.)
Coercion Mode
1
Sets the capacity control for
the physical hard disk used
for disk array building
[<<None (using the entire
capacity)>>] / 128MB-way (using
a capacity as a multiple of
128MB) / 1GB-way (using a
capacity as a multiple of 1GB)
Set Factory Defaults
2
Returns all the settings to
their Defaults values
-
S.M.A.R.T Polling
3
Sets the interval of S.M.A.R.T.
reporting
0 to 65535 / <<300>> / [600]
Cluster Mode
4
Sets the cluster mode
[<<Disabled (invalid)>>]
Alarm Control
Sounds the buzzer on the
controller in the event of a
fault at a connected device
[<<Disabled (not sounding)>>] /
Enabled (sounding) / Silence
(stop sounding temporarily)
Rebuild Rate
3
Priority of rebuilding
0 to 100 / [<<30>>]
Patrol Read Rate
3
Priority of patrol reading
0 to 100 / [<<30>>]
BGI Rate
3
Priority of background
initializing
0 to 100 / [<<30>>]
Cache Flush Interval
3
Flash timing for write-cache
data
1 to 255 / [<<4>>]
CC Rate
3
Priority of integrity inspection
0 to 100 / [<<30>>]
Spinup Drive Count
3
Number of hard disk motors
started at system startup
0 to 8 / [<<4>>]
Reconstruction Rate
3
Priority in expanding capacity
0 to 100 / [<<30>>]
Spinup Delay
3
Hard disk spinup timing at the
system boot
0 to xxx / [<<6>>]
NCQ
3
Setting the NCQ command
[<<Enabled>>] / Disabled
Notes:
1
.
This can be changed only when no disk arrays have been set at all.
2
.
Do not use Set Factory Defaults. This setting must be changed to the
recommended values.
3
.
Always use the "Default" setting.
4
.
Change the value to the recommended value.
Tip:
•
When changing a setting value, select the text box, click it to open the
dropdown list, and select the value; or click the cursor on a setting value
to change, and type a new value from the keyboard. Then click Submit.
MegaRAID WebBIOS for storage expansion blades
4-15
Hitachi Compute Blade 500 Series EFI User's Guide
Summary of Contents for Compute Blade 500 Series
Page 8: ...viii Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 14: ...xiv Preface Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 445: ...SAS configuration utility 7 11 Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 468: ...7 34 SAS configuration utility Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 475: ...BIOS settings for PXE boot 8 7 Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 476: ...8 8 BIOS settings for PXE boot Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 504: ...10 12 Fibre channel over Ethernet FCoE Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 505: ...Hitachi Compute Blade 500 Series EFI User s Guide ...