Menu items
Description
Setting/display value
page: schedule consistency check
.
Maintain PD Fail
History
1
Sets whether or not a failed
hard disk can be used.
[<<Enabled (Registers failed hard
disk information.)>>] /
Disabled (Not register failed hard
disk information.)
Stop On Error
2
Sets whether or not to boot
the OS when an error is
detected at the consistency
check.
[<<Disabled>>] / Enabled
Controller BIOS
3
Sets the disk array
controller BIOS
Not mounting the LSI SAS 2008
RAID mezzanine card and LSI
SAS 2004:
[<<Enabled>>] / Disabled
Mounting together with LSI SAS
2008 RAID mezzanine card or LSI
SAS 2004:
[<<Disabled>>] / Enabled
Disc Activity
1
Sets hard disk LED
switching.
[<<Disabled>>] / Enabled
Link Speed
Sets the physical drive link
speed.
Click Manage to go to Link
Speed:
Global Hot spare for
Emergency
1
Sets whether or not to
rebuild a different type of
physical drive for global hot
spare.
[<<Disabled>>] / Enabled
Unconfigured for
Emergency
1
Sets whether or not to
rebuild an unconfigured
physical drive.
[<<Disabled>>] / Enabled
Notes:
1
.
Do not set this item, which is not supported.
2
.
Make sure to use this item with the default setting.
3
.
When LSI SAS 2008 is installed in the half-wide blade, you must disable Controller
BIOS for LSI
SAS 2208 and confirm that Controller BIOS for LSI SAS 2008 is enabled. For details,
Controller properties submenu 2 on page 3-13
.
4
.
When booting OS through LSI SAS 2004 in half-wide blade, you must disable
Controller BIOS for LSI SAS 2208 and confirm that Boot Support of LSI SAS 2004 is
"Enabled BIOS & OS".
When booting OS through LSI SAS 2208 in storage expansion blade, you must
disable Boot Support for LSI SAS 2004 in half-wide blade and confirm that Controller
BIOS for LSI SAS 2208 is enabled.
4-18
MegaRAID WebBIOS for storage expansion blades
Hitachi Compute Blade 500 Series EFI User's Guide
Summary of Contents for Compute Blade 500 Series
Page 8: ...viii Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 14: ...xiv Preface Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 445: ...SAS configuration utility 7 11 Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 468: ...7 34 SAS configuration utility Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 475: ...BIOS settings for PXE boot 8 7 Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 476: ...8 8 BIOS settings for PXE boot Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 504: ...10 12 Fibre channel over Ethernet FCoE Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 505: ...Hitachi Compute Blade 500 Series EFI User s Guide ...