Menu items
View/description
Value/view/reference
iMR) / [Pause on errors
(Suspends when an error
occurs) (Recommendable
value with using SAS 3004
iMR) / <<Stop on errors
(Stops when an error
occurs)>>
Stop Consistency Check
on Error
Set a behavior when an error
is detected at consistency
check.
Enabled (Stops consistency
check) / [<<Disabled
(Continues running)>>]
Maintain Drive Fail
History
Failed hard disk is used or
not.
[<<Enabled (Saves failed
hard disk information)>>] /
Disabled (Not saves failed
hard disk information)
Load Balance
Load balancing
[<<Auto (valid)>>] /
Disabled (invalid)
Enable Auto Import
Loads foreign configuration
automatically.
[<<Enabled (valid)>>] /
Disabled (invalid)
Persistent Hot Spare
Sets hot spare automatically. [<<Enabled (valid)>>] /
Disabled (invalid)
Manage Link Speed
1
Transfer speed of the
physical drive
-
Spin Down
Unconfigured Good
Spin down setting for unused
hard disks
Enabled (valid) /
[<<Disabled (invalid)>>]
Spin Down Hot Spare
Drives
Spin down setting for a hard
disk assigned to hot spare
Enabled (valid) /
[<<Disabled (invalid)>>]
Drive Standby Time
Time that takes a drive goes
to standby mode
30 Minutes to 24 Hours /
[<<30 Mins>>]
Spinup Drive Count
Number of hard disk motors
to start at the system boot
[2]
Spinup Delay
A timing when hard disk
motors start up at the
system boot.
[6]
Patrol Read State
Patrol read status
-
Patrol Read Iteration
Number of patrol read
processes
-
Patrol Read Mode
Operational conditions for
patrol read
[<<Auto (automatic)>>] /
Disabled (invalid) / Manual
(valid)
Patrol Read Rate
Priority of patrol read
processes
[<<30>>]
Start Patrol Read
1
Starts Patrol Read.
-
Suspend Patrol Read
1
Suspends Patrol Read.
-
Resume Patrol Read
1
Resumes Patrol Read.
-
5-24
SAS 3004 iMR ROMB Configuration Utility
Hitachi Compute Blade 500 Series EFI User's Guide
Summary of Contents for Compute Blade 500 Series
Page 8: ...viii Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 14: ...xiv Preface Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 445: ...SAS configuration utility 7 11 Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 468: ...7 34 SAS configuration utility Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 475: ...BIOS settings for PXE boot 8 7 Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 476: ...8 8 BIOS settings for PXE boot Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 504: ...10 12 Fibre channel over Ethernet FCoE Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 505: ...Hitachi Compute Blade 500 Series EFI User s Guide ...