Status
Description
The physical drive is separated from the virtual drive due to a
failure.
Rebuild
Rebuilding is underway.
Unconfigured Good This is not used for a virtual drive
Unconfigured Bad
A fault has occurred.
The unrecognizable physical drive is restored to recognizable.
Missing
A fault has occurred.
A "normal" physical drive has been removed.
Error messages at the system boot
Here is a list of messages for MegaRAID WebBIOS displayed at system
startup.
Message
Description
A discovery error has occurred.
Power-cycle the system and all the
enclosures attached to this
system.
Cause:
The disk array controller was not recognized.
Action:
If this message appeared, contact your reseller
or call maintenance personnel.
In addition, if this message appeared, the
system startup cannot continue.
All of the disks from your previous
configuration are gone. If this is an
unexpected message, then power
off your system and check your
cables to ensure all disks are
present.
Press any key to continue or press
C to load the configuration utility
Cause:
No logical drives are recognized.
Action 1:
a
.
Enter a character, and then press the Enter
key.
The following message appears: Critical
Message handling completed. Please exit.
b
.
Press the ESC key.
The selection window appears.
c
.
Press the Y key.
System startup continues.
Action 2:
a
.
Press the C key, and then press the Enter
key.
b
.
The LSI MegaRAID <HITACHI SAS 3004
iMR ROMB> Configuration Utility restarts.
Action 3:
If this message is displayed even though the
physical drive is properly mounted, contact your
reseller or call maintenance personnel.
SAS 3004 iMR ROMB Configuration Utility
5-53
Hitachi Compute Blade 500 Series EFI User's Guide
Summary of Contents for Compute Blade 500 Series
Page 8: ...viii Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 14: ...xiv Preface Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 445: ...SAS configuration utility 7 11 Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 468: ...7 34 SAS configuration utility Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 475: ...BIOS settings for PXE boot 8 7 Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 476: ...8 8 BIOS settings for PXE boot Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 504: ...10 12 Fibre channel over Ethernet FCoE Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 505: ...Hitachi Compute Blade 500 Series EFI User s Guide ...