Message
Description
An enclosure was found that
contains both SAS and SATA
drives, but this controller does not
allow mixed drive types in a single
enclosure.
Correct the problem and restart
your system.
Press any key to continue or press
C to load the configuration utility.
Cause:
The disk array controller is operated by
incorrect parameters.
Action 1:
a
.
Enter a character, and then press the Enter
key.
The following message appears: Critical
Message handling completed. Please exit.
b
.
Press the ESC key.
The selection window appears.
c
.
Press the Y key.
System startup continues.
Action 2:
a
.
Press the C key, and then press the Enter
key.
b
.
The LSI MegaRAID <HITACHI SAS 3004
iMR ROMB> Configuration Utility restarts.
Action 3:
If this message appeared, contact your reseller
or call maintenance personnel.
A snapshot rollback is in progress
on VDs %s, controller cannot boot
until the rollback operation
completes. Press any key to enter
the configuration utility.
Cause:
The disk array controller parameter is incorrect.
Action 1:
a
.
Enter a character, and then press the Enter
key.
The LSI MegaRAID <HITACHI SAS 3004
iMR ROMB> Configuration Utility restarts.
Action 2:
If this message appeared, contact your reseller
or call maintenance personnel.
Cache data was lost because of an
unexpected power-off or reboot
during a write operation, but the
adapter has recovered.
This could be because of memory
problems, bad battery, or you may
not have a battery installed.
Press any key to continue or press
C to load the configuration utility.
Cause:
An invalid power-off or reboot was executed
during a write operation.
Action 1:
a
.
Enter a character, and then press the Enter
key.
The following message appears: Critical
Message handling completed. Please exit.
b
.
Press the ESC key.
The selection window appears.
c
.
Press the Y key.
System startup continues.
Action 2:
a
.
Press the C key, and then press the Enter
key.
5-54
SAS 3004 iMR ROMB Configuration Utility
Hitachi Compute Blade 500 Series EFI User's Guide
Summary of Contents for Compute Blade 500 Series
Page 8: ...viii Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 14: ...xiv Preface Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 445: ...SAS configuration utility 7 11 Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 468: ...7 34 SAS configuration utility Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 475: ...BIOS settings for PXE boot 8 7 Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 476: ...8 8 BIOS settings for PXE boot Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 504: ...10 12 Fibre channel over Ethernet FCoE Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 505: ...Hitachi Compute Blade 500 Series EFI User s Guide ...