Message
Description
The following VDs are missing:
If you proceed (or load the
configuration utility), these VDs
are removed from your
configuration.
If you wish to use them at a later
time, they have to be imported.
If you decide these VDs should be
present, power off your system
and check your cables to ensure
all disks are present.
Press any key to continue or press
C to load the configuration utility.
Cause:
Some logical drives are not recognized.
Action 1:
a
.
Enter a character, and then press the Enter
key.
The following message appears: Critical
Message handling completed. Please exit.
b
.
Press the ESC key.
The selection window appears.
c
.
Press the Y key.
System startup continues.
Action 2:
a
.
Press the C key, and then press the Enter
key.
b
.
The LSI MegaRAID <HITACHI SAS 3004
iMR ROMB> Configuration Utility restarts.
Action 3:
If this message is displayed even though the
physical drive is properly mounted, contact your
reseller or call maintenance personnel.
The following VDs are missing
complete spans.
If you proceed (or load the
configuration utility), these VDs
are removed from your
configuration and the remaining
drives marked as foreign.
If you wish to use them at a later
time, restore the missing spans
and use foreign import to recover
the VDs.
If you believe these VDs should be
present, please power off your
system and check your cables to
ensure all disks are present.
Press any key to continue, or 'C' to
load the configuration utility.
Cause:
Some logical drives are not recognized.
Action 1:
a
.
Enter a character, and then press the Enter
key.
The following message appears: Critical
Message handling completed. Please exit.
b
.
Press the ESC key.
The selection window appears.
c
.
Press the Y key.
System startup continues.
Action 2:
a
.
Press the C key, and then press the Enter
key.
b
.
The LSI MegaRAID <HITACHI SAS 3004
iMR ROMB> Configuration Utility restarts.
Action 3:
If this message is displayed even though the
physical drive is properly mounted, contact your
reseller or call maintenance personnel.
The native configuration is no
longer supported by the current
controller and firmware.
Please ensure that correct
controller firmware is being used.
Cause:
The settings for this disk array controller do not
support the original configuration information.
Action 1:
SAS 3004 iMR ROMB Configuration Utility
5-65
Hitachi Compute Blade 500 Series EFI User's Guide
Summary of Contents for Compute Blade 500 Series
Page 8: ...viii Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 14: ...xiv Preface Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 445: ...SAS configuration utility 7 11 Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 468: ...7 34 SAS configuration utility Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 475: ...BIOS settings for PXE boot 8 7 Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 476: ...8 8 BIOS settings for PXE boot Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 504: ...10 12 Fibre channel over Ethernet FCoE Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 505: ...Hitachi Compute Blade 500 Series EFI User s Guide ...