In the case that Target is set to Connect by OneCommandManager, iSCSI
Target is restored when OS rebooted even if disconnected by iSCSISelect
Utility.
Disconnection by OneCommandManager is required after disconnection by
Utility.
For details about disconnecting an iSCSI device, see the Hitachi Compute
Blade 500 OneCommandManager Guide.
1
.
Change Boot Target to No at the setting menu in step 8 of
. After that, select Save/Login and press Enter.
Tip: iSCSI Target is not disconnected when Boot Target is Yes.
Following message is displayed.
2
.
Press F6 and set Connection Status to Disconnected at the setting
menu in step 9 of
Boot device setting on page 9-9
.
Note: All the contents of iSCSI Target setting are deleted by DEL.
iSCSI settings
9-15
Hitachi Compute Blade 500 Series EFI User's Guide