“H” Group: Motor Constants Functions
The “H” Group parameters configure the
inverter for the motor characteristics. You must
manually set H003 and H004 values to match
the motor. Parameter H006 is factory-set. If you
want to reset the parameters to the factory
default settings, use the procedure in
“Restoring Factory Default Settings” on page 6-
8
. Use A044 to select the torque control
algorithm as shown in the diagram.
“H” Function
Defaults
Func.
Code
Name /
SRW Display
Description
Run
Mode
Edit
-FE
(EU)
-FU
(USA)
Units
Motor capacity
H003
AUX K
0.4 kW
Ten selections:
0.2/0.4/0.55/0.75/1.1/1.5/2.2/3.7/
5.5/7.5
U
kW
Motor capacity, 2nd motor
H203
2AUXK
0.4 kW
Ten selections:
0.2/0.4/0.55/0.75/1.1/1.5/2.2/3.7/
5.5/7.5
U
Specified by
the capacity
of each
inverter
model
kW
Motor poles setting
H004
AUX P
4p
Four selections:
2 / 4 / 6 / 8
U
4
4
poles
Motor poles setting, 2nd
motor
H204
2AUXP
4p
Four selections:
2 / 4 / 6 / 8
U
4
4
poles
Motor stabilization
constant
H006
AUX KCD
100
Motor constant (factory set),
range is 0 to 255
9
100
100
Motor stabilization
constant, 2nd motor
H206
2AUXKCD
100
Motor constant (factory set),
range is 0 to 255
9
100
100
Inverter Torque Control Algorithms