List of Holding Registers
Network Data
Func.
Code
Name
R/W
Description
Reg.
Range
Res.
C144
Terminal [11] ON delay
R/W Range is 0.0 to 100.0 sec.
1153h 0 to 1000 0.1 sec
C145
Terminal [11] OFF delay
R/W Range is 0.0 to 100.0 sec.
1154h 0 to 1000 0.1 sec
C148
Output relay ON delay
R/W Range is 0.0 to 100.0 sec.
1157h 0 to 1000 0.1 sec
C149
Output relay OFF delay
R/W Range is 0.0 to 100.0 sec.
1158h 0 to 1000 0.1 sec
Note 1:
Assume that the inverter current rating is 10000 (for C041).
The following table lists the holding registers for the “H” Group Motor Constants.
List of Holding Registers
Network Data
Func.
Code
Name
R/W
Description
Reg.
Range
Res.
H003
Motor capacity
R/W
1165h
0 to 13
H203
Motor capacity, 2nd
motor
R/W
0…0.20kW
1…0.37kW
2…0.40kW
3…0.55 kW
4…0.75 kW
5…1.10 kW
6…1.50 kW
7…2.2 kW
8…3.0 kW
9…3.7 kW
10…4.0 kW
11…5.5 kW
12…7.5 kW
13…11.0kW
1541h
0 to 13
H004
Motor poles setting
R/W
1166h
2, 4, 6, 8
1 pole
H204
Motor poles setting, 2nd
motor
R/W
Four selections:
2 / 4 / 6 / 8
1542h
2, 4, 6, 8
1 pole
H006
Motor stabilization
constant
R/W
1168h
0 to 255
1
H206
Motor stabilization
constant, 2nd motor
R/W
Motor constant (factory set),
range is 0 to 255
1544h
0 to 255
1
B
39
Appe
ndix B
B
−
39
Appendix B