Item
400V class Specifications
EU version
030HFEF
040HFEF
055HFEF
075HFEF
X200 inverters,
400V models
USA version
–
040HFU
055HFU
075HFU
kW
3.0
4.0
5.5
7.5
Applicable motor size *2
HP
4
5
7.5
10
380V
5.1
5.6
8.5
10.5
Rated capacity
(kVA)
480V
6.4
7.1
10.8
13.3
Rated input voltage *6
3-phase: 380V-15% to 480V
r
10%, 50/60Hz
r
5%
EU version
SFE series
: EN61800-3 category C2 filter
Integrated EMC
filter
USA version
–
Rated input current (A)
10.0
11.0
16.5
20.0
Rated output voltage *3
3-phase: 380 to 480V (proportional to input voltage)
Rated output current (A)
7.8
8.6
13
16
Efficiency at 100% rated output
96.8%
97.3%
97.3%
98.3%
at 70% output
68
74
101
127
Watt loss
(fc=3kHz)
Approximate (W)
at 100% output
96
107
150
189
Starting torque *7
100% at 6Hz
20%:
d
60Hz
Dynamic braking,
approx. % torque
(short time stop
from 50/60Hz) *8
Capacitive feedback type, dynamic braking unit and braking
resistor optional, individually installed
Braking
DC braking
Variable operating frequency, time, and braking force
Kg
2.4
2.4
4.2
4.2
EU version
(-HFEF)
lb
5.30
5.30
9.27
9.27
Kg
–
2.3
4.2
4.2
Weight
USA version
(-HFU)
lb
–
5.08
9.27
9.27
Torque characteristics
NOTE: The data are based on the Hitachi standard induction motor (4p). The torque
performance depends on the characteristics of the motor to be used.
1
9
Getting st
arted
Output frequency (Hz)
Output torque (%)
45
55
80
95
100
130
150
1
0
6
20
60
120
Continuous performance
Short time performance
Base frequency = 60Hz
Output frequency (Hz)
Output torque (%)
35
45
55
75
90
100
130
150
1
0
5
16.7
50
120
Continuous performance
Short time performance
Base frequency = 50Hz
35
0.2~4kW
5.5, 7.5kW
0.2~4kW
5.5, 7.5kW
0.2~4kW
5.5, 7.5kW
0.2~4kW
5.5, 7.5kW
1
−
9
Getting started