Multi-speed and Jog Frequency Setting
The X200 inverter has the capability to store and output up to 16 preset frequencies to
the motor (A020 to A035). As in traditional motion terminology, we call this
multi-speed
profile capability. These preset frequencies are selected by means of digital inputs to the
inverter. The inverter applies the current acceleration or deceleration setting to change
from the current output frequency to the new one. The first multi-speed setting is
duplicated for the second motor settings (the remaining 15 multi-speeds apply only to
the first motor).
The jog speed setting is used whenever the Jog command is active. The jog speed setting
range is arbitrarily limited to 10 Hz, to provide safety during manual operation. The
acceleration to the jog frequency is instantaneous, but you can choose from three modes
for the best method for stopping the jog operation.
“A” Function
Defaults
Func.
Code
Name /
SRW Display
Description
Run
Mode
Edit
-FE
(EU)
-FU
(USA)
Units
Multi-speed frequency setting
A020
SPD 00s
0000.0Hz
Defines the first speed of a multi-
speed profile, range is 0.0 / start
frequency to 400Hz
A020 = Speed 0 (1st motor)
9
0.0
0.0
Hz
Multi-speed frequency
setting, 2nd motor
A220
2SPD00s
0000.0Hz
Defines the first speed of a multi-
speed profile or a 2nd motor,
range is 0.0 / start frequency to
400Hz
A220 = Speed 0 (2nd motor)
9
0.0
0.0
Hz
Multi-speed frequency
settings
(for both motors)
Defines 15 more speeds,
range is 0.0 / start frequency to
400 Hz.
A021=Speed 1 ~ A035=Speed15
See
next
row
See
next
row
A021
to
A035
SPD 01s
000.0Hz
SPD 02s
000.0Hz
SPD 03s
000.0Hz
SPD 04s
000.0Hz
SPD 05s
000.0Hz
SPD 06s
000.0Hz
SPD 07s
000.0Hz
SPD 08s
000.0Hz
SPD 09s
000.0Hz
SPD 10s
000.0Hz
SPD 11s
000.0Hz
SPD 12s
000.0Hz
SPD 13s
000.0Hz
SPD 14s
000.0Hz
SPD 15s
000.0Hz
A021
A022
A023
A024
A025
A026
A027
A028
A029
A030
A031
A032
A033
A034
A035
9
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
Hz
Jog frequency setting
A038
Jog-F
001.00Hz
Defines limited speed for jog,
range is 0.00 / start frequency to
9.99 Hz
9
1.00
1.00
Hz
Jog stop mode
A039
Jog-Mode
FRS
Define how end of jog stops the
motor; three options:
00
}
Free-run stop
01
}
Controlled deceleration
02
}
DC braking to stop
U