Control Logic Signal Specifications
The control logic connectors are located just
behind the front housing cover. The relay
contacts are just to the left of the logic connectors.
Connector labeling is shown below.
Terminal Name
Description
Ratings
[P24]
+24V for logic inputs
24VDC, 30mA. (do not short to terminal L)
[PCS]
Intelligent input common
Factory set: Source type for –FE and –HE
models (connecting [P24] to [1]~[5] turns
each input ON). To change to sink type,
remove the short wire between [PCS] and
[L], and connect it between [P24] and [L]. In
this case, connecting [L] to [1]~[5] makes
each input ON.
[1], [2], [3], [4], [5]
Discrete logic inputs
27VDC max. (use PCS or an external
supply referenced to terminal L)
[L] (right) *1
GND for logic inputs
Sum of input [1]~[5] currents (return)
[11]
Discrete logic output
50mA max. ON state current,
27 VDC max. OFF state voltage
[CM2]
GND for logic output
100 mA: [11] current return
[AM]
Analog voltage output
0~10VDC 1mA maximum
[L] (left) *2
GND for analog signals
Sum of [OI], [O], and [H] currents (return)
[OI]
Analog input, current
4 to 19.6 mA range, 20 mA nominal,
input impedance 250
:
[O]
Analog input, voltage
0 to 9.8 VDC range, 10 VDC nominal,
input impedance 10 k
:
[H]
+10V analog reference
10VDC nominal, 10mA max.
[AL0]
Relay common contact
[AL1] *3
Relay contact, normally open
[AL2] *3
Relay contact, normally closed
250VAC,
2.5A (R load) max.
250VAC,
0.2A (I load, P.F.=0.4) max.
100VAC,
10mA min.
30VDC,
3.0A (R load) max.
30VDC,
0.7A (I load, P.F.=0.4) max.
5VDC, 100mA min.
Note 1:
The two terminals [L] are electrically connected together inside the inverter.
Note 2:
We recommend using [L] logic GND (to the right) for logic input circuits and
[L] analog GND (to the left) for analog I/O circuits.
Note 3:
Default relay N.O./N.C. configuration is reversed. See
page 4-35
.
4
6
Operations and
Monitori
ng
AL2 AL1 AL0
Relay
contacts
AM H
O OI
L
5
4
3
2
1
L
PCS P24 CM2
11
Analog
output
Analog
inputs
Logic inputs
Logic
output
Short bar : default position (Source logic)
4
−
6
Operations and
Monitoring