Deskstar 7K400 Hard Disk Drive Specification
243
12.60 Write Stream DMA (3Ah)
Table 180: Write Stream DMA Command (3Ah)
The Write Stream DMA command allows the host to write data using the DMA data transfer protocol. This com-
mand allows for the host to specify to the device that additional actions need to be performed prior to the comple-
tion of the command if the required bits are set.
If the Write Continuous bit is set to one, the device shall not stop execution of the command due to errors. If the
WC bit is set to one and errors occur in the transfer or writing of the data, the device shall continue to transfer the
amount of data requested and then provide ending status with the BSY bit cleared to zero, the SE bit set to one, the
ERR bit cleared to zero, and the type of error, ICRC, IDNF, or ABRT, reported in the error log. If the WC bit is set
to one and the Command Completion Time Limit expires, the device shall stop execution of the command and pro-
vide ending status with BSY bit cleared to zero, the SE bit set to one, the ERR bit cleared to zero, and report the
fact that the Command Completion Time Limit expired by setting the CCTO bit in the error log to one, In all cases,
the device shall attempt to transfer the amount of data requested within the Command Completion Time Limit
event if some data transferred is in error.
Command Block Output Registers
Command Block Input Registers
Register
7 6 5 4 3 2 1 0
Register
7 6 5 4 3 2 1 0
Data Low
- - - - - - - -
Data Low
- - - - - - - -
Data High
- - - - - - - -
Data High
- - - - - - - -
Feature
Current
V V V V - V V V
Error
See below
Previous
V V V V V V V V
Sector
Count
Current
V V V V V V V V
Sector
Count
HOB=0
- - - - - - - -
Previous
V V V V V V V V
HOB=1
- - - - - - - -
Sector
Number
Current
V V V V V V V V
Sector
Number
HOB=0
V V V V V V V V
Previous
V V V V V V V V
HOB=1
V V V V V V V V
Cylinder
Low
Current
V V V V V V V V
Cylinder
Low
HOB=0
V V V V V V V V
Previous
V V V V V V V V
HOB=1
V V V V V V V V
Cylinder
High
Current
V V V V V V V V
Cylinder
High
HOB=0
V V V V V V V V
Previous
V V V V V V V V
HOB=1
V V V V V V V V
Device/Head
- 1 - D - - - -
Device/Head
- - - - - - - -
Command
0 0 1 1 0 1 0 0
Status
See below ...
Error Register
Status Register
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
CRC
UNC
0
IDN
0
ABT
T0N
AMN
BSY RDY
DF
DSC
DRQ
COR IDX
ERR
V
V
0
V
0
V
0
V
0
V
V
V
-
0
-
V
Output Parameters To The Device
Feature Current
URG (bit7)
URG specifies an urgent transfer request. The Urgent bit specifies that the
command should be completed in the minimum possible time by the device and
shall be completed within the specified Command Completion Time Limit.
Summary of Contents for Deskstar 7K400
Page 2: ......
Page 18: ...Deskstar 7K400 Hard Disk Drive Specification 4 ...
Page 20: ...Deskstar 7K400 Hard Disk Drive Specification 6 ...
Page 21: ...Deskstar 7K400 Hard Disk Drive specification 7 Part 1 Functional specification ...
Page 22: ...Deskstar 7K400 Hard Disk Drive Specification 8 ...
Page 24: ...Deskstar 7K400 Hard Disk Drive Specification 10 ...
Page 34: ...Deskstar 7K400 Hard Disk Drive Specification 20 ...
Page 36: ...Deskstar 7K400 Hard Disk Drive Specification 22 ...
Page 58: ...Deskstar 7K400 Hard Disk Drive Specification 44 ...
Page 78: ...Deskstar 7K400 Hard Disk Drive Specification 64 ...
Page 80: ...Deskstar 7K400 Hard Disk Drive Specification 66 ...
Page 88: ...Deskstar 7K400 Hard Disk Drive Specification 74 ...
Page 116: ...Deskstar 7K400 Hard Disk Drive Specification 102 ...
Page 270: ...Deskstar 7K400 Hard Disk Drive Specification Write cache 94 Write DMA 226 ...