11. Insulation tests
Upon the completion of disassembly and repair, measure the insulation resistance and conduct a dielectric
strength test.
Insulation resistance : 7 M or more using a 500 VDC megohm tester
Dielectric strength
: 4,000 VAC/minute, with no abnormalities for 220 V - 240 V
(110 V for U.K. products)
: 2,500 VAC/minute, with no abnormalities for 110 V - 120 V (Except for U.K. products)
12. No-load current values
After no-load operation for 30 minutes, the no-load current values should be as follows:
Voltage (V)
110
120
220
230
240
Current (A) max.
3.0
2.8
1.6
1.5
1.4