--- 33 ---
B. Additional wiring work
General internal wiring can be accomplished by referring to
paragraphs 9-4 and 9-5-A. The following are special
instructions for switch connection.
(1) Wiring of reversing switch
Insert the lead wire (black) coming from the stator into
the terminal (1) of the reversing switch, and the lead wire
(white) into the terminal (2) as shown in Fig. 26.
Insert the lead wire (brown) coming from the carbon
brush or choke coil into the terminal (3) and the lead wire
(blue) into the terminal (4). After the insertion, pull each
lead wire slightly to check that the lead wires do not
come off. To disconnect the lead wires, insert a small
flat-blade screwdriver into the windows near the lead
wires and pull out the lead wires.
(2) Wiring of variable speed control switch
Insert each cord into the terminal 1 and terminal 2 of
the variable speed control switch as shown in Fig. 27
and tighten the screw (tightening torque: 0.6 0.2 N
•
m
(6 2 kgf
•
cm, 5.2 1.7 in-lbs.)). Insert the lead wire
(gray) coming from the Stator
[70]
into the terminal M1
and the lead wire (red) into the terminal M2. Insert each
lead wire (white) coming from the Noise Suppressor
[84]
into the terminals C1 and C2.
After the insertion, pull each lead wire slightly to check
that the lead wires do not come off. To disconnect the
lead wires, insert a small flat-blade screwdriver into the
windows near the lead wires and pull out the lead wires.
Fig. 26
(Stator) (CB or choke coil)
Black
Brown
Blue
White
(Stator)
(CB or choke coil)
Fig. 27
(Stator)
(Noise suppressor)
White
Red
Gray
Brown or black
(Cord)
9-6. Insulation Tests
On completion of resassembly after repair, measure the insulation resistance and conduct the dielectric strength
test.
Insulation resistance: 7 M
Ω
or more with DC 500 V megohm tester
Dielectric strength:
AC 4,000 V/1 minute, with no abnormalities
• • •
230 V (and 110 V for U.K. products)
9-7. No-load Current Values
After no-load operation for 30 minutes, the no-load current values should be as follows:
White
(Noise suppressor)
(Stator)
Blue or white
(Cord)
Voltage (V)
Current (A) max.
3.6
110
1.7
230
Summary of Contents for DH 24PD2
Page 26: ... 23 Fig 10 Dust collector B structure ...
Page 44: ......