K6602637
Rev.3
02.27.01
- 62 -
6.3.2.8.11 SMART Execute Off-line Immediate [B0h, Sub D4h]
Task File Registers
7
6
5
4
3
2
1
0
Command
B0h
Cylinder High
C2h
Cylinder Low
4Fh
Device/Head
-
X
-
DRV
XX
Sector Number
XX
Sector Count
XX
Features
D4h
DRV : Device selection bit
0 : DRV0
1:DRV1
This command causes the device to immediately initiate the optional set of off-line data collection activities
that collect attribute data in an off-line mode and then save this data to the device, or execute a self-
diagnostic
test routine in either captive or off-line mode.
Table 6.11
SMART EXECUTE OFF-LINE IMMEDIATE Sector Number register values
Value
Description of subcommand to be executed
0
Execute SMART off-line routine immediately in off-line mode
1
Execute SMART Short self-test routine immediately in off-line mode
2
Execute SMART Extended self-test routine immediately in off-line mode
3 - 63
Reserved
64 - 125
Reserved (Vendor specific)
126
Abort off-line mode off-line routine (Vendor specific)
127
Abort off-line mode self-test routine
128
Reserved
129
Execute SMART Short self-test routine immediately in captive mode
130
Execute SMART Extended self-test routine immediately in captive mode
131- 191
Reserved
192 - 255
Reserved (Vendor Specific)