5 - 1
Adjustment
5
5-1 Set-up for Adjustment
(1) Test equipment/jigs necessary for adjustment
1) Dual-trace oscilloscope
2) Color bar generator
3) Monitor TV (with A/V jacks)
4) Alignment tapes
5) Guide roller screwdriver
6) Blank tape (VHS)
(2) Connections of test equipment
Connect the equipment as follows when otherwise not specified.
1) Connect a color bar generator to the video input 1 jack.
2) Connect a monitor TV to the video output 1 jack.
3) Connect a monitor TV (able to handle a stereo signal) to the audio output 1 jack.
(3) Cautions on adjustment
1) The following conditions apply when otherwise not specified.
probe of oscilloscope: 10:1
Synchronization of oscilloscope: Internal sync
2) When performing more than one adjustment, follow the specified oder.
(4) List of Adjustment jigs
Alignment tape
Guide roller screwdriver
Parts No. 7069064