5 - 7
(6) Front Block
Caution
A fl ash unit is mounted in the DZ-GX3300E front block. The fl ash unit generates high voltage:
Take shock-preventive measure, such as wearing gloves, etc., and take great care during work:
The fl ash unit maintains a high voltage even if the power supply (AC adapter/charger, battery, etc.)
Fig. 5-3-6
Front right side
Disassembly and Reassembly > Disassembly
2) [A]
3) [G]
[GX3300E]
is removed.
1) Remove the AVJ-H/M/L circuit board (c) from
MAN circuit board (b) in the direction of the
arrow.
2) Open the jack cover (d) and then remove the
four screws [A].
3) With DZ-GX3300E, remove the screw [G]
4) Remove the front block (a) in the direction of
the arrow.
2) [A]
3) [G]
[GX3300E]
2) [A]
2) [A]
2) [A]
(c)
(a)
(d)
(b)
1)
4)
[G] M1.7×4
(Silver)
[A] M1.7×4
(Silver)
(a)
(e)
Flash unit
(a) Front block
(b) MAN circuit board
(c) AVJ-H/M/L circuit board
(d) Jack cover
(e) FRT-H/M/L circuit board