It is recommended to use AC and DC power sources within the following scope.
Applicable
instruments
Alternating current (AC)
Direct current (DC)
Light, Electric
Heater, Radio,
Television
Motors with
single phase
Battery
Model
E24
E35
E40
E50
E57
E24
E35
E40
E50
E57
E24
E35
E40
E50
E57
Scope of applicability
50Hz
Up to 2,200W
Up to 2,800W
Up to 3,300W
Up to 4,200W
Up to 5,100W
Up to 700W
Up to 900W
Up to 1,100W
Up to 1,400W
Up to 1,700W
12V
Up to 8.3A
Remarks
• The instruments which
require much starting
current and some kinds of
motors may be unable to
be used even if they are
within the applicable
scope.
• The AC no fuse breaker
turns OFF when the
current exceeding the
applicable scope is used
or when the applied
instrument is defective.
WARNING: HITACHI electronic controlled products should not be used with portable generators.
Irregular generator power could cause these products to fail.
Regarding other manufacturer's products, please contact the manufacturer to see if it is
safe to use the electronic controlled products with portable generators.