18
English
ENGINE OIL CHANGE
Change engine oil every 50 hours.
(for a new engine, change oil after 25 hours.)
1. Drain oil by removing the oil drain plug and the oil filler cap while the engine
is warm.
2. Reinstall the oil drain plug and fill the engine with oil unit it reaches the upper
level on the oil filler cap.
●
Use fresh and high quality lubricating oil to the specified quantity.
If contaminated or deteriorated oil is used or the quantity of the engine oil
is not sufficient, the engine damage will result and its life will be greatly
shortened.
OIL FILLER CAP
(OIL GAUGE)
OIL FILLER
NECK
DRAIN PLUG
OIL
Wash your hands with soap and water after handling used oil.
Please dispose of used motor oil and containers in a manner that will not harm the natural environment. We
suggest you take it in a sealed container to your local service station or recycling center for reclamation. Do not
throw it in the trash, pour it on the ground or down the drain.
NOTE: Never operate the generator without oil cap tightly secured. Failure to do so could cause oil to spill
out of the engine.
AIR FILTER
Adirty air cleaner will restrict airflow to the carburetor. To prevent carburetor malfunction, service the air filter
regularly. Service more frequently when operating the generator in extremely dusty areas.
NOTE: Never run the generator without the air cleaner. Rapid engine wear will result.
1. Take out the air cleaner, clean it well in kerosene and dry it.
2. After wetting the element by clean engine oil, squeeze it tight by hand.
3. Lastly, put the element in the case and install it securely.
ELEMENT
CLEANER
COVER
GRID
Fig. 25
Fig. 26
Fig. 27
Summary of Contents for E24
Page 22: ...22 English ...
Page 43: ...43 ...
Page 44: ...612 Code No C99160091 Printed in Japan Mfg Code KN55083AA Hitachi Koki Co Ltd ...