Chapter6 Communication Mode
6 - 2
EH-SIO will not communicate until initial setting is completed. After the initial setting is completed, the operation will
start according to the setting.
When the communication mode is set for free protocol mode or modbus master mode, communication is controlled by
TRNS 9 command. In the case of modbus slave mode and Hi-Protocol mode, a system performs automatically from
the watch of a request to response transmission. In the case of simple data link mode, the I/O information of data link
area is automatically updated by the system.
In addition, in case of modbus slave mode, Hi-Protocol mode, simple data link mode, operation works even if CPU
module is in stop. (Please reset EH-SIO, in order to cancel the setup.)