Battery 

 

 

 
 

7. Battery

 

These devices are equipped with rechargeable Lithium battery, not user-replaceable.

 

The following information is maintained by the battery: 

 

hardware  real-time clock (date and time) 

 

 

Charge: 
At first installation must be charged for 48 hours. 
When the battery is fully charged, it ensures a period of 3 months of data back-up at 25°C. 

 
 
 
 

 

Fig. 7.1: EH-TP504

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Fig. 7.2: EH-TP507,

 

EH-TP510,

 

EH-TP513,

 

EH-TP515

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

 

ATTENTION

 

!

 

Dispose of batteries according to local regulations.

 

 

Battery

 

Battery

 

Summary of Contents for EH-TP500 Series

Page 1: ...page HITACHI OPETATOR INTERFACES EH HMI EH TP500 Series OPERATING INSTRUCTIONS Basic User s Manual for EH TP500 Series Touchscreen Products Hitachi Europe GmbH EH TP500 Series OPERATING INSTRUCTIONS Ver 1 00 ...

Page 2: ...ice The information contained in this document is provided for informational purposes only While efforts were made to verify the accuracy of the information contained in this documentation it is provided as is without warranty of any kind Third party brands and names are the property of their respective owners http www hitachi ds com ...

Page 3: ...ns 8 4 Technical Data 10 4 1 Dimensions 13 4 2 Installation Environment 15 4 3 Installation Procedure 16 5 Connections 17 5 1 Serial Port 19 5 2 Ethernet Port 20 5 3 Optional plugin module 21 6 Power Supply Grounding and Shielding 23 7 Battery 24 8 Cleaning Faceplates 25 9 Getting Started 25 10 System Settings 26 11 LED Indicator on Front Panel 29 12 Unpacking and Packing Instructions 29 ...

Page 4: ...scribes the main features of EH TP500 Series operator panels The Manual refers to the following models EH TP504 Operator interface with TFT color 4 3 display touchscreen EH TP507 Operator interface with TFT color 7 widescreen display touchscreen EH TP510 Operator interface with TFT color 10 4 display touchscreen EH TP513 Operator interface with TFT color 13 3 widescreen display touchscreen EH TP51...

Page 5: ...attention are divided into three levels of severity DANGER indicates a failure to observe safety rules and such failure may cause death or serious injuries ATTENTION indicates a failure to observe safety rules and that deficiency may cause damage CAUTION indicates a failure to observe safety rules and that deficiency may cause defects to the equipment or inconsistencies CAUTION ATTENTION DANGER ...

Page 6: ... multiple languages to meet global requirements Far East languages are supported Tools available in HiMobile Studio support easy third party translations and help reducing development and maintenance costs of the application Data display in numerical text bar graph analog gauges and graphic image formats Rich set of state of the art HMI features data acquisition alarm handling scheduler and timed ...

Page 7: ... the case that special in measures are taken in order to ensure conformity to EN 61000 6 3 The products are in compliance with the Restrictions on Certain Hazardous Substances RoHS Directive 2002 95 EC In compliance with the above regulations the products are CE marked Product Identification The product may be identified through a plate attached to the rear cover You will have to know the type of ...

Page 8: ...m p p 9 150 Hz 1 g 50 g 11 ms 3 pulses per axis IP66 front panel EN60068 2 6 EN60068 2 27 EN 60529 The front face of the unit installed in a solid panel has been tested using conditions equivalent to the standards shown in the Environmental conditions Even though the level of resistance unit is equivalent to these standards oils that should have no effect on the panel can possibly harm the unit Th...

Page 9: ...Phase 0 180 Test executed on the 230Vac side of the Exor International S p A Power Supply EN 61000 4 11 Durability information Backlight service life 40000 Hrs or more LED type Time of continuous operation until the brightness of the backlight reaches 50 of the rated value when the surrounding air temperature is 25 C see Note 1 Front foil 10 years if the surrounding air temperature is 25 C without...

Page 10: ...Port RS 232 RS 485 RS 422 DB9 female software configurable RS 232 RS 485 RS 422 DB9 female software configurable Ethernet port 2 10 100 Mbit with integrated switch 2 10 100 Mbit with integrated switch USB port 1 Host interface version 2 0 and 1 1 2 Host interface 1 version 2 0 1 version 2 0 and 1 1 Expansion slot 1 Optional Plugin 2 Optional Plugin Battery rechargeable rechargeable Real Time Clock...

Page 11: ...485 RS 422 DB9 female software configurable RS 232 RS 485 RS 422 DB9 female software configurable Ethernet port 2 10 100 Mbit with integrated switch 2 10 100 Mbit with integrated switch USB port 2 Host interface 1 version 2 0 1 version 2 0 and 1 1 2 Host interface 1 version 2 0 1 version 2 0 and 1 1 Expansion slot 2 Optional Plugin 2 Optional Plugin Battery rechargeable rechargeable Real Time Cloc...

Page 12: ...ilable memory Serial Port RS 232 RS 485 RS 422 DB9 female software configurable Ethernet port 2 10 100 Mbit with integrated switch USB port 2 Host interface 1 version 2 0 1 version 2 0 and 1 1 Expansion slot 2 Optional Plugin Battery rechargeable Real Time Clock yes Voltage 10 32Vdc Current rating at 24VDC 1 4A Weight 3 5 Kg For applications requiring compliance with EN 61131 2 and specifically in...

Page 13: ...EH TP500 Series Operating Instructions VER 1 00 13 Technical Data 4 1 Dimensions MODEL A B C D E F EH TP504 149mm 5 86 109mm 4 29 136mm 5 35 96mm 3 78 56mm 2 40 4mm 0 16 Cut out ...

Page 14: ... 187mm 7 36 147mm 5 79 176mm 6 90 136mm 5 35 47mm 1 85 4mm 0 16 EH TP510 287mm 11 3 232mm 9 13 276mm 10 86 221mm 8 70 56mm 2 20 4mm 0 16 EH TP513 336mm 13 22 267mm 10 51 326mm 12 83 256mm 10 07 56mm 2 20 4mm 0 16 EH TP515 392mm 15 43 307mm 12 08 381mm 15 296mm 11 65 60mm 2 36 4mm 0 16 Cut out ...

Page 15: ... panel In order to meet the front panel protection classifications proper installation procedure must be followed the borders of the cutout must be flat screw up each fixing screw until the bezel corner get in contact with the panel the cutout for the panel must be of the dimensions indicated in this manual The IP66 is guaranteed only if max deviation from the plane surface to the cut out O0 5mm t...

Page 16: ...rating Instructions VER 1 00 16 Technical Data 4 3 Installation Procedure Place the fixing brackets as shown in figure Fig 4 3 Fig 4 3 CAUTION Screw each fixing screw until the bezel corner gets in contact with the panel ...

Page 17: ...EH TP500 Series Operating Instructions VER 1 00 17 Connections 5 Connections Fig 5 1 1 Serial Port 2 2x Ethernet Port 3 USB Port 4 Power Supply 5 Expansion slot for Plugin module 6 SD Card Slot EH TP504 ...

Page 18: ...ing Instructions VER 1 00 18 Connections Fig 5 2 1 Serial Port 2 2x Ethernet Port 3 USB Port version 2 0 1 1 4 USB Port version 2 0 High speed only 5 Power Supply 6 2x Expansion slot for Plugin module 7 SD Card Slot EH TP5xx ...

Page 19: ...ector RS 232 RS 422 and RS 485 The serial port is software programmable Make sure you select the appropriate interface in the programming software RS 232 RS 422 RS 485 SERIAL PORT To operate in RS485 pins 4 3 and 8 7 must be connected externally The communication cable must be chosen for the type of device being connected Pin Description 1 GND 2 3 TX 4 RX 5 6 5V output 7 CTS 8 RTS 9 Pin Descriptio...

Page 20: ...uctions VER 1 00 20 Connections 5 2 Ethernet Port The Ethernet port has two status indicators Please see description in figure 1 8 OFF Valid link has NOT been detected ON Valid link has been detected ON No activity BLINKING Activity ...

Page 21: ...nal plugin module multiple modules configurations are possible Slot 2 and Slot 4 are available only if plugin module has the bus extension connector Each slot carries three communication channels 1 serial interface 1 CAN interface 1 SPI interface Note It is not possible to stack two modules that are using the same type of interface ...

Page 22: ...al Y EH TPI485 Serial RS485 2 Serial Y EH TPIPB Profibus DP 1 SPI N Max modules refers to max number of modules can be plugged into the HMI all slots If you are planning to use EH TPI232 and EH TPI485 additional serial ports you will obtain following COM Slot association a module plugged in Slot 1 or into Slot 2 will be COM2 a module plugged in Slot 3 or into Slot 4 will be COM3 If you are plannin...

Page 23: ...round the terminal 3 on the power supply terminal block The power supply circuit may be floating or grounded In the latter case connect to ground the power source common as shown in figure see below with a dashed line When using the floating power scheme note that the panes internally connects the power common to ground with a 1M resistor in parallel with a 4 7nF capacitor The power supply must ha...

Page 24: ...information is maintained by the battery hardware real time clock date and time Charge At first installation must be charged for 48 hours When the battery is fully charged it ensures a period of 3 months of data back up at 25 C Fig 7 1 EH TP504 Fig 7 2 EH TP507 EH TP510 EH TP513 EH TP515 ATTENTION Dispose of batteries according to local regulations Battery Battery ...

Page 25: ... must be properly installed on a computer running Microsoft Windows There are two options to transfer a HiMobile application project to a HMI device Ethernet Connect the HMI device to the computer with an Ethernet network connection From HiMobile Studio choose the command Run Download to target You may have to ensure that the proper firewall policy has been configured in the computer to allow HiMo...

Page 26: ...art the associated function System Settings has two modes of operation User Mode HiMobile runtime is running or the HMI device is in factory default status System Mode HiMobile runtime is not running or the HMI device has a software failure System Mode includes all options available in User Mode and offers in additions commands dedicated to system upgrade and recovery Activation of System Settings...

Page 27: ...stalled Network configure IP Address of Ethernet interface BSP settings show the BSP Board Support Package version check the operating hours for the device and for the display backlight manage the buzzer Time change the device date and time including time zone Daylight Saving Time and NTP Server Regional Settings customize Windows Regional Settings such as date format Display settings configure au...

Page 28: ...tloader reserved to authorized technical personnel Upload Configuration OS reserved to authorized technical personnel Upload Main OS reserved to authorized technical personnel Upload Splash Image copy to an USB Memory or SD Card the current splash screen image in binary format Upload OS Partition reserved to authorized technical personnel Upload Data Partition reserved to authorized technical pers...

Page 29: ... on Front Panel The table below shows the symbol of the LED indicator dedicated to special functions LED Indicator Status Meaning Symbol Color Red ON Hardware fault Battery low Green ON Normal operation BLINK Communication error 12 Unpacking and Packing Instructions To repack the unit please follow the instructions backwards 1 2 3 ...

Page 30: ...Hitachi Europe GmbH Am Seestern 18 Tel 49 0 211 52 83 0 D 40547 Düsseldorf Germany Fax 49 0 211 52 83 649 http www hitachi ds com ...

Reviews: