GENERAL / Tightening
W1-2-6
PIPING JOINT
IMPORTANT: The torques given in the chart are
for general use only.
Do not use these torques if a differ-
ent torque is given for a specific ap-
plication.
Union Joint
Metal sealing surfaces (4) and (5) of adapter (1) and
hose (2) fit together to seal pressure oil. Union joints
are used to join small-diameter lines.
IMPORTANT: 1. Do not over-tighten nut (3). Ex-
cessive force will be applied to
metal sealing surfaces (4) and (5),
possibly cracking adapter (1). Be
sure to tighten nut (3) to specifi-
cations.
2. Scratches or other damage to
sealing surfaces (4) or (5) will
cause oil leakage at the joint.
Take care not to damage them
when connecting/disconnecting.
M202-07-051
W105-01-01-017
Wrench Size
mm
Wrench Size mm
Tightening
Torque
Description
Union Nut
Hose Fittings
N m (kgf m, lbf ft)
30
male
17
17
24.5 (2.5,18)
19
19
29.5 (3.0,21.5)
22
22
39 (4.0,28.5)
27
27
93 (9.5,69)
32
32
137 (14,101)
36
36
175 (18,129)
41
41
205 (21,151)
37
female
17
14
24.5 (2.5,18)
19
17
29.5 (3.0,21.5)
22
19
39 (4.0,28.5)
27
22
93 (9.5,69)
32
27
137 (14,101)
36
32
175 (18,129)
41
36
205 (21,151)
NOTE: Tightening torque of 37
male coupling without union is similar
to tightening torque of 37
female.
37
30
Female Union Joint
Male Union Joint
1
3
5
2
Joint Body
4