background image

Section 2   Connection Procedures 

2.1 

Connecting User System Interface Cable to Emulator Station 

WARNING

 

   

Observe the precautions listed below.  Failure to do so  

  will result in a FIRE HAZARD and will damage the user  
  system and the emulator product or will result in  
  PERSONAL INJURY.  The USER PROGRAM will be  
  LOST.   
  1.   Always switch OFF the user system and the emulator 
   

product before the USER SYSTEM INTERFACE CABLE  

   

is connected to or removed from any part.  Before  

   

connecting, make sure that pin 1 on both sides are  

   

correctly aligned.  

  2.  The user system interface cable dedicated to the  
   

emulator must be used.   

To connect the cable body to the emulator station, follow the instructions below. 

1.  Make sure the user system and emulator station are turned off. 

CAUTION 

   

When connecting or removing the user system interface 

  cable, apply force only in the direction suitable for 
  connection or removal, while making sure not to bend or 
  twist the cable or connectors. Otherwise, the connectors will 
 be damaged. 

2. 

After making sure the direction of the cable body connector is correct, firmly insert the cable 
body connector into the emulator station socket (figure 2). 

3. 

If the emulator has holes for fastening screws, fasten the cable body to the emulator station by 
using the attached screws for fixing the cable body. 

 

Summary of Contents for FP-64E

Page 1: ... system interface cable must only be used for the above purpose Improvement Policy Hitachi Ltd including its subsidiaries hereafter collectively referred to as Hitachi pursues a policy of continuing improvement in design performance functions and safety of the user system interface cable Hitachi reserves the right to change wholly or partially the specifications design user s manual and other docu...

Page 2: ...from you Hitachi is not liable for any claim made by a third party or made by you for a third party DISCLAIMER HITACHI MAKES NO WARRANTIES EITHER EXPRESS OR IMPLIED ORAL OR WRITTEN EXCEPT AS PROVIDED HEREIN INCLUDING WITHOUT LIMITATION THEREOF WARRANTIES AS TO MARKETABILITY MERCHANTABILITY FITNESS FOR ANY PARTICULAR PURPOSE OR USE OR AGAINST INFRINGEMENT OF ANY PATENT IN NO EVENT SHALL HITACHI BE ...

Page 3: ...rt may be reproduced or duplicated in any form in hard copy or machine readable form by any means available without Hitachi s prior written consent Other Important Things to Keep in Mind 1 Circuitry and other examples described herein are meant merely to indicate the characteristics and performance of Hitachi s semiconductor products Hitachi assumes no responsibility for any intellectual property ...

Page 4: ...w this symbol to avoid possible injury or death DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate ...

Page 5: ...n PERSONAL INJURY The USER PROGRAM will be LOST 1 Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance 2 Always switch OFF the E6000 emulator and user system before connecting or disconnecting any CABLES or PARTS 3 Always before connecting any CABLES make sure that pin 1 on both sides are correctly aligned V ...

Page 6: ...H8S 2212 Series FP 64E User System Interface Cable HS2212ECH61H for E6000 Emulator User s Manual ADE xxx xxx Rev 1 0 2 4 03 Hitachi Ltd HS2212ECH61HE ...

Page 7: ...of bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support 4 Design your application so that the product is used within the ranges guaranteed by Hitachi particularly for maximum rating operating supply voltage range heat radiation characteristics installation conditions and other characteristics Hita...

Page 8: ... is a user system interface cable that connects an H8S 2214 series E6000 emulator HS2214EPI62H hereinafter referred to as the emulator to the IC socket for a FP 64E package for the H8S 2212 series MCU on the user system The user system interface cable should be used with H8S 2214 series E6000 emulator HS2214EPI62H hereinafter referred to as the emulator ...

Page 9: ... Soldering IC Socket 5 2 2 3 Inserting Cable Head 6 2 2 4 Fastening Cable Head 6 2 2 5 Fastening Cable Body 8 2 3 Recommended Dimensions for User System Mount Pad 9 2 4 Dimensions for User System Interface Cable Head 10 2 5 Resulting Dimensions after Connecting User System Interface Cable 11 Section 3 Installing the MCU to the User System 12 Section 4 User Interface Circuit 14 Section 5 Verifying ...

Page 10: ...hows the configuration of the HS2212ECH61H user system interface cable for the FP 64E package To emulator station Cable body EIO board Screws M3 x 6 mm for fixing the cable body User system IC socket Cable head Screws M2 x 12 mm with flat washers Screws M2 x 6 mm with flat washers Socket cover for fastening cable head Figure 1 HS2212ECH61H User System Interface Cable 1 ...

Page 11: ... 2 Cable head 1 Consisting of two printed circuit boards 3 IC socket 1 For the FP 64E package 4 Socket cover 1 For installing a FP 64E packaged MCU 5 Screws M2 x 12 mm 4 For fastening cable head with four flat washers 6 Screws M2 x 6 mm 4 For installing a FP 64E packaged MCU with four flat washers 7 CTS screws M3 x 6 mm 2 For fixing the cable body 8 Documentation 1 User s manual for HS2212ECH61H t...

Page 12: ...nterface cable dedicated to the emulator must be used To connect the cable body to the emulator station follow the instructions below 1 Make sure the user system and emulator station are turned off CAUTION When connecting or removing the user system interface cable apply force only in the direction suitable for connection or removal while making sure not to bend or twist the cable or connectors Ot...

Page 13: ...Emulator station Cable body connector Screws for fixing the cable body User system interface cable E 6 0 0 0 Figure 2 Connecting User System Interface Cable to Emulator Station 4 ...

Page 14: ...esult in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable head to the user system follow the instructions below 2 2 1 Installing IC Socket After checking the location of pin 1 on the IC socket apply epoxy resin adhesive to the bottom of the IC socket for a FP 64E package and fasten it to the user system before soldering 2 2 2 Soldering IC Socket After fastening solder the IC sock...

Page 15: ...eater than that needed when first tightening If a screw is tightened too much the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder 3 If the emulator does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necessary Fasten the user system interface cable head to the IC socket...

Page 16: ...Pin 1 Cable head IC socket IC149 064 175 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd Screws M2 x 12 mm with flat washers User system Figure 3 Connecting User System Interface Cable to User System 7 ...

Page 17: ...2 2 5 Fastening Cable Body Connect the cable body to the cable head 8 Cable body Cable head Remove jig Push the remove jig User system Removing Figure 4 Fastening Cable Body ...

Page 18: ...an IC socket for a FP 64E package IC149 064 175 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd Note that the dimensions in figure 5 are somewhat different from those of the actual chip s mount pad 9 Unit mm 0 50 15 7 50 0 05 0 50 0 05 0 50 15 7 50 0 05 10 10 max 13 50 min 0 30 0 05 13 50 min 10 10 max Figure 5 Recommended Dimensions for Mount Pad ...

Page 19: ...er System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6 Unit mm Tolerance 0 5 mm 63 5 63 5 19 3 19 3 25 0 25 0 Figure 6 Dimensions for User System Interface Cable Head 10 ...

Page 20: ...er connecting the user system interface cable head to the user system are shown in figure 7 11 Cable head User system Unit mm Tolerance 0 5 mm 14 0 35 1 IC socket IC149 064 175 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd Figure 7 Resulting Dimensions after Connecting User System Interface Cable ...

Page 21: ...w head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necessary Check the location of pin 1 before inserting the MCU into the IC socket on the user system as shown in figure 8 After inserting the MCU fasten the sock...

Page 22: ...Pin 1 IC socket IC149 064 175 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd User system Screws M2 x 6 mm with flat washers Socket cover MCU Figure 8 Installing MCU to User System 13 ...

Page 23: ...he H8S 2212 user interface signal includes a interface circuit as shown in figure 9 14 H8S 2218 0 1 µF 5 0 1 µF DrVcc DrVss D15 to D8 47 Ω 47 kΩ Vcc Vcc D15 PD7 D8 PD0 to Evaluation chip E6000 emulator HS2214EPI62H USD USD UBPM VBUS USPND USD USD UBPM VBUS USPND DrVcc DrVss HS2212ECH61H 8 User system Figure 9 User Interface Signal ...

Page 24: ...log box To use the external clock on the user system Select external clock target or target 2 with the CLOCK option in the Configuration Properties dialog box and supply the external clock from the user system to the emulator Supply the external clock to the system clock by inputting the external clock from the EXTAL terminal on the cable head or connecting a crystal oscillator to the EXTAL and XT...

Page 25: ... heavy or sharp metal objects on the user system interface cable 5 While the emulator station is connected to the user system with the user system interface cable force must not be applied to the cable head Place the emulator station user system interface cable and user system as shown in the example in figure 11 16 User system Emulator station Place components so that the cable body and cable hea...

Page 26: ...gisters a bus controller must be set For details refer to section 3 MCU Operating Mode section 6 Bus Controller and section 14 Universal Serial Bus USB in the H8S 2212 Series Hardware Manual When using the emulator the following register settings are required Pin function control register PFCR H FDEB H 02 Bit 2 of the port 7 data direction register P7DDR H FE36 1 Port C data direction register PCD...

Reviews: