Section 5 Verifying Operation
1. When using the H8S/2214 E6000 emulator for the H8S/2212 Series, turn on the emulator
according to the procedures described in the H8S/2214 E6000 Emulator User's Manual
(HS2214EPI62HE).
2. Verify the user system interface cable connections by accessing the ports to check the bus states
of the pins. If an error is detected, recheck the soldered IC socket and the location of pin 1.
3. The emulator connected to this user system interface cable supports two kinds of clock sources
as the MCU clock: an emulator internal clock and an external clock on the user system. For
details, refer to the H8S/2214 E6000 Emulator User’s Manual (HS2214EPI62HE).
To use the emulator internal clock
Select the clock in the emulator station with the [CLOCK] option in the [Configuration
Properties] dialog box.
To use the external clock on the user system
Select external clock (target or target/2) with the [CLOCK] option in the [Configuration
Properties] dialog box, and supply the external clock from the user system to the emulator.
Supply the external clock to the system clock by inputting the external clock from the
EXTAL terminal on the cable head or connecting a crystal oscillator to the EXTAL and
XTAL terminals. To supply the external clock to the subclock, connect the 32.768-kHz
crystal oscillator to the OSC1 and OSC2 terminals. For details, refer to section 19, Clock
Pulse Generator, in the H8S/2212 Series Hardware Manual.
The user system interface cable has the oscillator circuits shown in figure 10. This circuit is
located on the lower board of the HS2212ECH61H.
R2 270
Ω
R1 1 M
Ω
HCU04
HCU04
HCU04
To E6000
emulator
To E6000
emulator
EXTAL
XTAL
R6 470 k
Ω
R5 3.3 M
Ω
HCU04
HCU04
HCU04
OSC1
OSC2
R12 2.2 k
Ω
R13 10 k
Ω
System clock oscillator
Subclock oscillator
Figure 10 Clock Oscillator Circuits