Hitachi Lightning 9900™ V Series Remote Console Error Codes 

45 

6005  8789 

Combination of the specified expansion volumes is 

not valid.  

The combination of the specified volumes for 

LUN Expansion is not valid. Verify the 

parameters and retry the operation. 

I 4 

6005  8790 

The specified expansion volume (Port/Group/LUN) of 

the RCU is not usable.  

The specified expansion volume (Port/ID/LUN) of 

the RCU is not usable. For example,  

1. The specified expansion volume of the RCU is 

blocked. 

2. The specified expansion volume of the RCU is 

in CC=3 condition.  

3. The specified expansion volume of the RCU 

requires intervention. 

4. The specified RCU does not support 

TrueCopy for the expansion volume. 

I 4 

6005  8791 

The specified M-VOL is still online from another 

HOST.  

Please vary the concerned path offline from the 

other host, and then retry the operation. 

I 4 

6005  8792 

Archival function is not installed in specified 

controller(s).  

Install the Archival function in the MCU and the 

RCU, then retry the operation. 

I 4 

6005  8793 

The TrueCopy function is not installed in specified 

controller(s).  

Install TrueCopy in the MCU and the RCU, then 

retry the operation. 

I 4 

6005  8794 

The TrueCopy function is not installed in specified 

controller(s).  

Install TrueCopy in the MCU and the RCU, then 

retry the operation. 

I 4 

6005  8795 

The M-VOL should have ShadowImage-

S/390

®

/ShadowImage Split pair(PSUS) status when 

defined as T-VOL. It should not be Reserve VOL, nor 

ShadowImage-S/390

®

/ShadowImage Reverse Copy 

status. 

Check the status of the specified M-VOL from the 

host or the SVP. 

I 4 

6005  8796 

The R-VOL should not be ShadowImage-

S/390

®

/ShadowImage T-VOL, Reserve VOL, nor 

ShadowImage-S/390

®

/ShadowImage Reserve Copy 

status.  

Check the status of the specified R-VOL from the 

host or the SVP. 

I 4 

6005  8797 

The M-VOL should be the ShadowImage-

S/390

®

/ShadowImage T-VOL of the pair established, 

with one S-VOL to one T-VOL. 

Check the status of the specified M-VOL from the 

host or the SVP. 

I 4 

6005  8798 

The MCU is already used by ShadowImage-

S/390

®

/ShadowImage.  

The Add Pair operation failed because the MCU 

is already being used by ShadowImage. Verify 

the status of the MCU and retry the operation.  

I 4 

6005  8799 

The M-VOL is already in use by CruiseControl. 

Verify the status of the specified M-VOL. 

6005  8800 

The R-VOL is already in use by CruiseControl. 

Verify the status of the specified R-VOL.  

6005 8801  The 

R-VOL 

is reserved, or the RCU or the path 

between MCU-RCU is in a heavy load  condition. 

Verify the status of the specified R-VOL. If the 

device is not reserved, retry the operation. 

I 4 

6005  8802 

CT group is not active.  

The add pair operation failed because the C/T 

Group is not active. Add the C/T group, then retry 

the operation.  

E 4 

6005  8803 

Too many RCUs in this CT Group.  

The add pair operation failed because there are 

too many RCUs in this C/T group. If the timer 

type is System, then 4 RCU have already been 

added. If the timer type is Local or None, then 1 

RCU has already been added. 

I 4 

Summary of Contents for Freedom Storage Lightning 9900 V series

Page 1: ...Hitachi Freedom Storage Lightning 9900 V Series Remote Console Error Codes ...

Page 2: ......

Page 3: ...vailability This document contains the most current information available at the time of publication When new and or revised information becomes available this entire document will be updated and distributed to all registered users Trademarks Hitachi Data Systems is a registered trademark and service mark of Hitachi Ltd The Hitachi Data Systems design mark is a trademark and service mark of Hitach...

Page 4: ...tion 1 2 Added error codes 0001 5075 0001 5508 0001 5509 0002 5510 0003 2085 2094 0405 5013 1110 9080 3010 9019 5310 1110 Revised message text and recommended action for error codes 0002 2016 0003 2085 2094 0110 5085 1110 1110 Referenced Documents Hitachi Lightning 9900 V Series User and Reference Guide MK 92RD100 Hitachi Lightning 9900 V Series Hitachi Remote Console Storage Navigator User s Guid...

Page 5: ...r contact your Hitachi Data Systems account team For further information on the Hitachi Remote Console Storage Navigator software please refer to the Hitachi Lightning 9900 V Series Hitachi Remote Console Storage Navigator User s Guide MK 92RD101 Note In this document the term 9900V refers to the entire Hitachi Lightning 9900 V Series subsystem family unless otherwise noted Note The use of the Lig...

Page 6: ...vi Preface ...

Page 7: ...Hitachi Lightning 9900 V Series Remote Console Error Codes vii Contents Chapter 1 Remote Console Messages and Error Codes 1 1 Remote Console Messages 1 1 2 Error Codes 2 Acronyms and Abbreviations 73 ...

Page 8: ...viii Contents ...

Page 9: ...evel Information Warning Fatal error The server is unable to accept the request from the Remote Console One possible cause is that some processing is in progress at the server This message does not indicate an error Message text Descriptive text may include variables s character string and d numeral The values of these variables are determined when processing is performed Part code The ID of the a...

Page 10: ...ure Level 0001 1000 An error occurred If this problem persists please call the Support Center If nothing changes despite retrying call the service personnel E 2 0001 1001 An error occurred If this problem persists please call the Support Center If nothing changes despite retrying call the service personnel E 2 0001 1002 An error occurred If this problem persists please call the Support Center If n...

Page 11: ...ter Call the service personnel E 2 0001 4009 An error occurred If this problem persists please call the Support Center Call the service personnel E 2 0001 4010 An error occurred If this problem persists please call the Support Center The error occurs only in the internal process E 2 0001 4011 An error occurred If this problem persists please call the Support Center Log in again E 2 0001 4012 The n...

Page 12: ...port Center Call the service personnel E 2 0002 2011 The server configuration is invalid Please call the Support Center Call the service personnel E 2 0002 2012 An error occurred If this problem persists please call the Support Center Call the service personnel E 2 0002 2013 An error occurred If this problem persists please call the Support Center The volume which links as an expanded LU extend ov...

Page 13: ... The error does not occur normally because it is guarded in the screen Contact the program maker E 2 0003 1004 An error occurred If this problem persists please call the Support Center A file access error occurs for the file required by the agent Contact the Hitachi Data Systems Support Center E 2 0003 1005 An error occurred If this problem persists please call the Support Center A nickname is not...

Page 14: ... it The error does not occur normally because it is guarded in the screen Contact the program maker E 2 0003 1031 An error occurred If this problem persists please call the Support Center Command device setting is requested for Reserve volume of CruiseControl On Demand volume Or it is requested for volumes other than open volumes including un installed volumes The error does not occur normally bec...

Page 15: ...t the specified content and issue the request again E 5 0003 1048 An error occurred If this problem persists please call the Support Center Fibre topology information is invalid The specified value is not in the specification The error does not occur normally because it is guarded in the screen Contact the program maker E 2 0003 1049 An error occurred If this problem persists please call the Suppo...

Page 16: ...rred If this problem persists please call the Support Center LUN is invalid The specified value is not in the specification The error does not occur normally because it is guarded in the screen Contact the program maker E 2 0003 1104 An error occurred If this problem persists please call the Support Center Port blockade error occurs Call the service personnel E 2 0003 1105 An error occurred If thi...

Page 17: ...pport Center The emulation type is specified incorrectly in Virtual LVI LUN operation The error does not occur normally because it is guarded in the screen Contact the program maker E 2 0003 1134 An error occurred If this problem persists please call the Support Center The emulation type of a volume which links as an expanded LU is not Open volume The error does not occur normally because it is gu...

Page 18: ...get and then set E 6 0003 1354 Failed to add the WWN to the initiator port The port you are trying to set is for Fibre TrueCopy You need to change the attribute when adding a WWN Attribute Target or RCU Target E 6 0003 1355 Host group to the initiator port cannot be changed The port you are trying to set is for Fibre TrueCopy You need to change the attribute when adding a WWN Attribute Target or R...

Page 19: ...rver procedure Check if I O from the host to target path volume does not occur E 6 0003 2011 You cannot perform processing because a volume pair is being created for remote copy operations correction copy is in progress or the LDEV is closed Release the volume pair or wait for a while and then retry processing If you still cannot perform processing please call the technical support center Check th...

Page 20: ...ying is in progress for Remote Copy ShadowImage ShadowImage S 390 R pairs Please wait for a while and then retry Please wait for awhile and then retry W 6 0003 2086 The configuration of ShadowImage ShadowImage S 390 R is defined Reset the configuration definetion and then retry the operation Reset the configuration definetion and then retry the operation W 6 0003 2087 The system is online from the...

Page 21: ...it is guarded in the screen Contact the program maker E 2 0003 3005 An error occurred If this problem persists please call the Support Center When WWN is registered in LUN Security operation the number of WWNs you can register is exceeded The error does not occur normally because it is guarded in the screen Contact the program maker E 2 0003 3006 An error occurred If this problem persists please c...

Page 22: ...Center Call the service personnel E 2 0006 4000 The server configuration is invalid Please call the Support Center Call the service personnel E 2 0006 4002 The server configuration is invalid Please call the Support Center Register the authentication data Call the service personnel E 2 0007 6012 An error occurred If this problem persists please call the Support Center E 2 0010 4005 The user ID is ...

Page 23: ...exit this program Log in again and retry I 2 0110 5088 The maximum permissible capacity of program product became insufficient because of the installation of PDEV Install the program product whose permissible capacity is insufficient and retry I 5 0110 6027 A network error ocurred the server is not ready or an error occurred in the server You cannot connect to the server because of the factors suc...

Page 24: ...tered Specify other nickname and register again 0190 5012 Enter the nickname with up to 16 alphanumeric characters Specify the nickname using up to 16 characters and less and retry 0190 5013 Enter the product name with up to 16 alphanumeric characters Specify the product name using up to 16 characters and less and retry 0190 5014 Enter the location name with up to 16 alphanumeric characters Specif...

Page 25: ...ce File Download Permission Reboot the process 0190 9000 Are you sure you want to register the storage device entry None 0190 9001 Are you sure you want to delete the selected storage device entry None 0190 9100 Are you sure you want to compress the trace files None 0210 7060 An error occurred in the Client logic Call the service personnel E 2 0290 5010 Enter the user ID Specify the user ID 0290 5...

Page 26: ...n despite retrying call the service personnel 0290 6150 Failed to open the user account list file If the same error occurs again despite retrying call the service personnel 0290 6160 Failed to open the user account list file If the same error occurs again despite retrying call the service personnel 0290 6170 Failed to open the user account list file If the same error occurs again despite retrying ...

Page 27: ...ror occurred If this problem persists please call the Support Center Reboot the PC If the error cannot be recovered replace the PC E 2 0305 7060 An error occurred If this problem persists please call the Support Center 1 Please retry again 2 Please Reboot PC E 2 0305 7102 An error occurred If this problem persists please call the Support Center Review the configuration information and make the set...

Page 28: ...problems according to the following procedure 1 Reboot the PC 2 Check the LAN card LAN cable 3 Check the IP address of the PC 4 Replace the PC 5 Power off on the DKC Care should be taken 6 When using Remote Console Server you should check the connection between CLIENT and SERVER first Then execute the above 1 to 5 E 2 0305 7208 An error occurred If this problem persists please call the Support Cen...

Page 29: ... the requirement W 5 0405 5073 To install de install this program product you must install de install another program product first Program Product Name Please install the related program product at first W 5 0405 5074 The specified PP ID is invalid Retry again If it occurred again call Hitachi Data Systems Support Center W 5 0405 5075 This key code is invalid Confirm if the key code is correct or...

Page 30: ...ase call the Support Center E 2 0405 7101 An error occurred If this problem persists please call the Support Center Order the appropriate license that meets the requirement E 2 0405 7201 An error occurred If this problem persists please call the Support Center Call the service personnel E 2 0405 7202 An error occurred If this problem persists please call the Support Center Order the appropriate li...

Page 31: ...rred If this problem persists please call the Support Center Please select OK E 2 0505 6023 An error occurred If this problem persists please call the Support Center Check the FD When the failure is not recovered reboot the PC If it cannot be recovered replace the PC E 2 0505 6024 An error occurred If this problem persists please call the Support Center Check the FD When the failure is not recover...

Page 32: ... 9010 There is a charge for this operation Do you want to continue W 5 1010 1023 The specified fiber address is wrong Correct the specified content and issue the request again Currently Bad Value Send report in Set Response W 5 1010 1065 The specified Host Group is already used Correct the specified contents and request the setting of the configuration information again W 5 1010 5010 The specified...

Page 33: ... I 0 1010 9150 Select the free LUN I 0 1010 9151 Only the LUN LDEV is specified Select the corresponding LDEV LUN I 0 1110 1064 The specified WWN is already in use Correct the specified contents and request the setting of the configuration information again W 5 1110 1065 The specified name is already in use Correct the specified contents and request the setting of the configuration information aga...

Page 34: ... system cannot add WWN to LUN group Check the content of the operation W 5 1110 5061 The system cannot add WWN to WWN Check the content of the operation W 5 1110 5062 The WWN already exists in the port Check the content of the operation W 5 1110 5063 The WWN already has this LUN Check the content of the operation W 5 1110 5064 The WWN group already contains this LUN Check the content of the operat...

Page 35: ...ed LDEVs Correct the specified content and retry W 5 2010 5033 There are no LDEVs available to create the LUSE Check the specified LDEVs Correct the specified content and retry W 5 2010 5040 Too many LDEVs are selected for one LUSE volume Max 36 Reduce the number to 36 and less and retry W 5 2010 5050 No LDEV is specified Select LDEV and retry W 5 2010 5051 You cannot delete the first LDEV of a LU...

Page 36: ...Check the content of the operation W 5 3010 5053 The specified SSID is already used Check the content of the operation W 5 3010 5054 You must delete the paths associated with the LDEVs or release the LUSE Volume or release the Reserved Volume of CruiseControl before you delete the LDEV itself Please try again Check the content of the operation W 5 3010 5055 You cannot perform volume initialization...

Page 37: ...lete I 0 5105 2002 An error occurred If this problem persists please call the Support Center The size of a CV which links as an expanded LU is not the same Or you are trying to link CV and normal volume The error does not occur normally because it is guarded in the screen Contact the program maker E 2 5105 2015 A connection error has occurred Retry the same operation If the same error occurs despi...

Page 38: ...error occurs call the service personnel E 2 5105 8919 The subsystem status is invalid Please call the Support Center Retry the same operation several times If the same error occurs call the service personnel E 2 5202 1231 The target volume s is already being used by Data Migration Retry the same operation If nothing changes contact the service personnel E 6 5202 1232 The target volume s is already...

Page 39: ...1 The target volume s is already being used by HXRC Retry the same operation If nothing changes contact the service personnel E 6 5205 1122 The target volume s is already being used by HXRC Retry the same operation If nothing changes contact the service personnel E 6 5205 1207 The volume types do not match Retry the same operation If nothing changes contact the service personnel E 6 5205 1208 The ...

Page 40: ... being used by ShadowImage or ShadowImage S 390 Retry the same operation If nothing changes contact the service personnel E 6 5205 1230 The target volume s is already being used by ShadowImage or ShadowImage S 390 Retry the same operation If nothing changes contact the service personnel E 6 5205 1234 The target volume s is already being used by Remote Copy Retry the same operation If nothing chang...

Page 41: ...ersonnel E 4 5205 2033 The server is now gathering the latest data Internal processing is being executed Please wait a while and then click the Refresh button Wait for a while and press the Refresh button W 4 5205 3002 An error occurred If this problem persists please call the Support Center When Virtual LVI LUN operation Volume Initialize is performed the number of volumes which should be returne...

Page 42: ... call the service personnel E 4 5205 7404 Failed to get information from hihsmpgr ini Retry the same operation several times If the same error occurs call the service personnel E 4 5205 7405 Failed to get information from hihsmldv ini Retry the same operation several times If the same error occurs call the service personnel E 4 5205 7406 Failed to get configuration information Retry the same opera...

Page 43: ...he same operation several times If the same error occurs call the service personnel E 4 5205 7426 Failed to delete plan Retry the same operation several times If the same error occurs call the service personnel E 4 5205 8001 An error occurred while connecting to the subsystem Please retry a little later Retry the same operation several times If the same error occurs call the service personnel E 6 ...

Page 44: ...it is guarded in the screen Contact the program maker E 2 5305 5101 The target WWN is not registered Check the specified content and retry W 6 5305 5102 The target PA group s is not registered Check the specified content and retry W 6 5305 5104 The target PA group s is already reserved Check the specified content and retry W 6 5305 5105 The target port s does not equip the monitored WWN s Check th...

Page 45: ...al times If the same error occurs call the service personnel E 2 5307 5102 The target PA group s is not registered Check the specified content and retry W 6 5307 5128 The number of PA group s exceeds the maximum Check the specified content and retry I 6 5310 1110 You can not use the following characters for the name You cannot use spaces for the first and the last characters in the name Remove the...

Page 46: ...ration If nothing changes call the service personnel E 2 6005 5099 An error occurred If this problem persists please call the Support Center You are trying to set multiple volumes from a port group to pair of ID LUN The error does not occur normally because it is guarded in the screen Contact the program maker E 2 6005 6012 An error occurred If this problem persists please call Support Center If n...

Page 47: ...ter specified by the data migration operation is invalid For example the R VOL that is specified may already be in use as the R VOL of another pair Please check the status of the volumes and retry the operation I 4 6005 8708 The pair status of the R VOL is not valid Check the pair status for TrueCopy If the requested R VOL is in a permissible status please retry the operation I 4 6005 8709 Remote ...

Page 48: ...ishing failed Check the path connections between the MCU and the RCU then retry the operation E 4 6005 8723 The Edit Path operation was rejected because the specified path is the last path of some Remote Copy pairs Add another path or delete all pairs on the RCU Then retry the operation I 4 6005 8724 Specified number of Path is less than the Minimum Paths on RCU Option screen The specified number ...

Page 49: ... Center E 4 6005 8736 The specified RCU or SSID contains some Remote Copy volume pairs Invalid serial number or SSID for this operation Either the RCU is not a proper machine type for TrueCopy or the RCU s controller is not the proper type for data migration Check the serial number and SSID of the RCU and set the correct value I 4 6005 8737 An internal error occurred An internal error has occurred...

Page 50: ...ion does not support the specified operation The version of the microcode on the subsystem does not support the specified function or operation Please contact the Hitachi Data Systems Support Center I 4 6005 8748 Specified M VOL may be in use by HOST Data migration cannot start because the volume is online Please vary the path offline and retry I 4 6005 8749 Specified R VOL is still online from HO...

Page 51: ...ot be set on please contact the Hitachi Data Systems Support Center I 4 6005 8764 The Specified R VOL is not usable The specified R VOL is not usable because of one or the following reasons 1 The specified volume has not been installed 2 The specified volume is defined as a command device for Command Control Interface CCI W 4 6005 8765 DataMigration is not supported under the M VOL Device emulatio...

Page 52: ...Support Center I 4 6005 8778 One side of Cache on RCU is blocked There is an invalid cache status on the RCU Check the status and recover the cache then retry the operation W 4 6005 8779 TrueCopy is not supported under the RCU controller type This controller type does not support TrueCopy operations I 4 6005 8780 TrueCopy S 390 function is not installed in specified controller The TrueCopy option ...

Page 53: ...fined as T VOL It should not be Reserve VOL nor ShadowImage S 390 ShadowImage Reverse Copy status Check the status of the specified M VOL from the host or the SVP I 4 6005 8796 The R VOL should not be ShadowImage S 390 ShadowImage T VOL Reserve VOL nor ShadowImage S 390 ShadowImage Reserve Copy status Check the status of the specified R VOL from the host or the SVP I 4 6005 8797 The M VOL should b...

Page 54: ...eate Resume Pair Pairresync operation in a few minutes Add resume pair operation failed The specified volume or another volume in the same group being changed to simplex suspend status in RCU A few minutes later please renew and check the TrueCopy screen and if specified volume is in a permissible status please retry the operation I 4 6005 8810 TrueCopy S 390 Asynchronous function is not installed...

Page 55: ...opy function is not installed in MCU of the microprogram version install the appropriate version If the program product is not installed in MCU install the microprogram I 4 6005 8824 The TrueCopy S 390 Periodic Differential Copy function is not installed in the specified RCU If the TrueCopy S 390 PeriodicCopy function is not installed in RCU of the microprogram version install the appropriate vers...

Page 56: ...hi Data Systems Support Center E 4 6005 8838 Specified volume is not part of a Remote Copy pair The specified volume is not part of a TrueCopy pair Please check the volume I 4 6005 8839 Invalid RCU serial number SSID Link Address or Controller ID Check the serial number SSID and link address of the RCU and set the correct value Then retry the operation If the same error occurs contact the Hitachi ...

Page 57: ...S operation failed because M VOL is in Simplex SMPL status The operation failed because of one of the following reasons 1 The specified volume is simplex 2 There is no duplex or duplex pending or suspend volume in the group Verify the status and retry the operation I 4 6005 8855 Delete Pairsplit S operation failed because specified volume or other volume in the same group is in status transition T...

Page 58: ...already active in MCU The operation failed because a duplicate C T Group is already active in the MCU Verify the status of the C T group and retry the operation E 4 6005 8869 CT Group is not active Verify that the C T group is active in the MCU E 4 6005 8870 CT Group Option cannot be changed unless all asynchronous pairs in the group are suspended or deleted The group operation failed because the ...

Page 59: ...othing changes call the Hitachi Data Systems Support Center E 4 6005 8890 The specified port is being initialized Please wait until the initialization of the port ends and retry the operation E 4 6005 8891 Logical paths exist on the MCU port Please delete the logical paths on the specified port and retry the operation E 4 6005 8892 R VOLs exist on the RCU port Are you sure you want to continue thi...

Page 60: ...r by the cylinder create by performing the difference management instruction in cylinder or turning off the bit 5 of the switch for MCU remote copy function E 5 6005 8907 The extended SM is not equipped in RCU Install SM to RCU with the installation instruction of SM for remote copy extension Install TrueCopy Function E 5 6005 8908 Invalid parameter Please check the value of the specified paramete...

Page 61: ... Please try again after registering CT groups Register a CT group and retry W 5 6010 5066 The RCU and one of the CT group channel types do not match Please correct RCU or CT group Select the same path type for RCU and CT group W 5 6010 5131 The combination of parameters which you specified is not permitted Please specify the parameters by a different combination Check the condition for setting par...

Page 62: ... I 0 6010 9073 Are you sure you want to suspend the specified volume pairs If you want to suspend the specified pair select OK If not select Cancel I 0 6010 9074 Are you sure you want to erase data on the R VOL If you want to delete the contents of the remote volume select OK If not select Cancel I 0 6010 9075 Are you sure you want to delete the SSIDs of a specified RCU If you want to delete the s...

Page 63: ... not synchronized full volume initializations are required before re using them The same as the message W 0 6010 9305 There are no initiator ports Set the port to Initiator before registering RCU W 0 6010 9306 The Remote Copy function is not installed in this controller You cannot create pairs There is no remote copy license Set the license W 0 6010 9307 You specified the same volumes more than on...

Page 64: ...y please call the Hitachi Data Systems Support Center E 4 7005 8001 A time out error occurred Retry the operation If you get the same message again reboot the PC If necessary please call the Hitachi Data Systems Support Center E 4 7005 8100 A time out error occurred Retry the operation If you get the same message again reboot the PC If necessary please call the Hitachi Data Systems Support Center ...

Page 65: ...OL Delete the created L2 pair and retry the operation I 0 7010 7310 Unregistered error code Contact Hitachi Data Systems Support Center W 0 7010 7311 The settings could not be applied Wait for a while and retry the operation If the same error occurs despite retrying contact Hitachi Data Systems Support Center W 0 7010 7312 The password could not be acquired Contact Hitachi Data Systems Support Cen...

Page 66: ...e maximum I 0 7010 8517 The number of S VOL cylinders exceeds the maximum I 0 7010 8518 You cannot create a pair because the track format is different for each Make sure that the specified emulation type is the same for both Check the emulation type I 0 7010 8519 You cannot set a pair because the number of cylinders is different for each Make sure that the capacity is the same for both Check the v...

Page 67: ... initial shared memory setup Contact Hitachi Data Systems Support Center I 0 7010 8543 The shared memory size is different Contact Hitachi Data Systems Support Center I 0 7010 8544 16 Mbytes of shared memory are available I 0 7010 8545 A power supply failure is detected Contact Hitachi Data Systems Support Center I 0 7010 8546 The command was rejected The PS OFF is in progress Retry the operation ...

Page 68: ...ource volume for hierarchical control Check the corresponding condition I 0 7010 8574 The volume is defined as a destination volume for hierarchical control Check the corresponding condition I 0 7010 8575 The selected volume is not a reserved volume I 0 7010 8576 No reserved volume is available for use I 0 7010 8577 The number of reserved volumes to be defined exceeds the maximum Stop the operatio...

Page 69: ...eady a P VOL Specify other P VOL and retry the operation Or delete the pair of the specified volume and then retry the operation I 0 7010 8600 The RAID level of the specified volume is not supported Check the RAID level and specify a volume of the supported RAID level and then retry the operation I 0 7010 8601 The target P VOL cannot be paired with a backup server volume I 0 7010 8602 The volume i...

Page 70: ...aired Check the specified volume number I 0 7010 8625 The P VOL S VOL and S VOL T VOL have the same number Check the specified volume number I 0 7010 8626 The SMPL command was rejected because the high speed Split was in progress After the high speed Split is completed retry the operation I 0 7010 8627 The Reverse Resync command was rejected because the high speed Split was in progress After the h...

Page 71: ...ecause the P VOL was shared with a secondary volume of a Remote Copy pair You cannot execute the specified operation Release the Remote Copy pair for the operation I 0 7010 8646 The Reverse Copy request was rejected because the P VOL was shared with a Remote Copy pair in the non suspend status Delete the Remote Copy pair I 0 7010 8647 The Reverse Copy request was rejected because the S VOL was sha...

Page 72: ...volume size Check the capacity of S VOL and T VOL Specify a volume with the same capacity and retry the operation W 0 7110 5116 You cannot create another pair because the number of pairs exceeds the maximum You cannot create the specified pair Delete the created pair and then retry the operation W 0 7110 5119 The S VOL is not selected Select the S VOL and retry the operation W 0 7110 5120 The T VO...

Page 73: ...lid Contact Hitachi Data Systems Support Center I 0 7110 8506 The command was rejected The specified T VOL is being used from the host or by a Hitachi TrueCopy S 390 volume I 0 7110 8507 The Pairsplit command was issued to the pairs in the split status You cannot execute the Pairsplit operation because the pair is already in the Split status I 0 7110 8508 The AddPair command was issued to the pair...

Page 74: ...ntact Hitachi Data Systems Support Center I 0 7110 8531 Internal logical error Contact Hitachi Data Systems Support Center I 0 7110 8532 The S VOL and T VOL are being used from the host or by Remote Copy Check the target volume or stop using it in Remote copy I 0 7110 8533 The emulation type of the specified reserved volume is not supported Specify the emulation type of the supported volume I 0 71...

Page 75: ...T VOL is command device I 0 7110 8557 The volume is not implemented You cannot execute the operation for the volume which is not implemented I 0 7110 8558 The volume cannot be used Contact Hitachi Data Systems Support Center and check if the volume status is normal I 0 7110 8559 The volume is being formatted Wait until the volume is formatted and retry the operation I 0 7110 8561 The command code ...

Page 76: ...system is invalid I 0 7110 8587 The number of pairs that can be set in the same group is invalid I 0 7110 8588 The specified group number is not set I 0 7110 8589 The specified group name is invalid I 0 7110 8590 The group name and the number do not match I 0 7110 8591 The specified pair is already set in another group I 0 7110 8592 The command was rejected because the licensed capacity was exceed...

Page 77: ...610 The T VOL is a source volume for hierarchical control Check the corresponding condition I 0 7110 8611 The specified volume is a target volume I 0 7110 8612 The specified volume is not a T VOL I 0 7110 8613 The RAID level of the specified target volume is not supported I 0 7110 8614 The target volume is used as a Remote Copy M VOL Delete the TrueCopy pair I 0 7110 8615 The target volume is used...

Page 78: ...s settings You cannot execute the specified operation Release the FlashAccess setting for the operation I 0 7110 8639 The command was rejected because the target T VOL has FlashAccess settings You cannot execute the specified operation Release the FlashAccess setting for the operation I 0 7110 8640 The command was rejected because a pair sharing the same S VOL was in the Reverse Copy status You ca...

Page 79: ...g the indicated operation Refer to the error code for each operation in Preset Volume List I 0 7110 9101 Do you want to cancel To cancel press the OK button I 0 7110 9102 Do you want to apply To execute the operation in Preset press the OK button I 0 7110 9108 The option has been changed If you continue processing before applying the change the option will be reset to the current setting Do you wa...

Page 80: ...nter Please check the inputted value and retry E 2 9005 6502 This key code is invalid Please wait for a moment and retry W 5 9005 7111 An error occurred If this problem persists please call the Support Center Call the service personnel E 2 9005 7112 An error occurred If this problem persists please call the Support Center Call the service personnel E 2 9005 7113 An error occurred If this problem p...

Page 81: ...el 1 level 2 LAN local area network LBA logical block address LCP local control port LDEV logical device LU logical unit LUN logical unit number LUSE LUN Expansion MCU main control unit MIB message information block MU mirror unit M VOL main volume NVS nonvolatile storage PA Priority Access PDEV physical device P P Program Product PS power supply PSUE pair suspended error status PSUS pair suspende...

Page 82: ...emory SMPL simplex SNMP simple network management protocol SSID subsystem ID S VOL secondary volume TrueCopy source volume ShadowImage S 390 SVP service processor TC390 TrueCopy S 390 T VOL target volume VDEV virtual device WWN worldwide name ...

Reviews: