--- 13 ---
8-6. Insulation Tests
On completion of disassembly and repair, measure the insulation resistance and conduct the dielectric strength
test.
Insulation resistance:
10 M
or more with DC 500 V Megohm Tester
Dielectric strength:
AC 4,400 V/3 seconds, with no abnormalities
• • • • • • • • • • • • • •
220 V --- 240 V
AC 3,000 V/3 seconds, with no abnormalities
• • • • • • • • • • • • • •
110 V --- 127 V
8-7. No-Load Current Value
After no-load operation for 30 minutes, the no-load current value should be as follows:
Voltage
Current (A) max.
110 V
120 V
3.0
2.8
220 V
1.5
230 V
1.5
240 V
1.5