112
【
Display items
】
No.
Item of display
Description
1
Device
Logical device name
2
WWPN
World Wide Port Name
3
Status
Port Status
LinkUp: Normal state
LinkDown: FC cable is not plugged.
WaitLinkUp: Waiting to Linkup
after Linkdown is detected.
Isolate(C ): Isolated by executing command.
Isolate(SFPFail) : SFP failure is detected.
Isolate(SFPNotSupport):
Unsupported SFP is plugged.
Isolate(SFPDown): SFP is not plugged.
Isolate(CHK-STOP): Adapter is check-stop state.
5
SFP Part Number
SFP Parts Number
6
SFP Serial Number
SFP Serial Number
7
SFP Date Code
SFP Date Code
8
Transceiver Replacement
Not replaceable : SFP is not hot-replaceable
Replaceable : SFP is hot-replaceable
You can replace SFP only when port status is
Isolate(C) or Isolate(CHK-STP).
[Error Messages]
■Firmware does not support SFP transceiver hot-swap
<Solution>Update firmware of the adapter.
■SFP is not plugged or SFP is not embedded (Mezzanine card or embedded FC-Switch).
<Solution> Comfirm whether SFP is plugged.
■SFP information is not displayed correctly.
<Solution> SFP may be damaged. Replace SFP transceiver.
Device: hfcldd0 WWPN: XXXXXXXXXXXXXXXX Status: Isolate(SFPFail)
SFP Part Number : incorrect data(xxxxxxxxxxxxxxxx)
Serial Number : incorrect data()
Date Code : incorrect data()
Transceiver Replacement : not replaceable
Device: hfcldd0 WWPN: XXXXXXXXXXXXXXXX Status: LinkUp
This Firmware version does not support hot swap feature of SFP Transceiver.
Device: hfcldd0 WWPN: XXXXXXXXXXXXXXXX Status: Isolate(SFPDown)
SFP Part Number : N/A
Serial Number : N/A
Date Code : N/A
Transceiver Replacement : not replaceable
Summary of Contents for GGX-CC9M4G2X1
Page 151: ...130 ...
Page 157: ...136 Example ...