53
(2) Update the FLASH-ROM.
(3) After the FLASH-ROM update is successfully completed, you need to transfer the
FLASH-ROM data. Refer to the example 1.
# ./hfcmgr -f all update /root/54100A30.220742.EF.500008700030F17A.BK
Time:XXXX/XX/XX XX:XX:XX
hfcmcup Ver. 1.4.0.9 Copyright(C) 2003,2004,2005. Hitachi, Ltd.
>>>>>>>>>>>>>>> hfcldd0
hfcldd0 HITACHI FC Adapter
*** NOTICE *** NOTICE *** NOTICE ***
The microcode installation occurs while the
adapter and any attached drives are available
for use. It is recommended that this installation
be scheduled during non-peak production periods.
As with any microcode installation involving
drives, a current backup should be available.
Use 'y' to continue the installation.
Use 'n' or Ctrl-c to cancel the installation.
(Y/N) : y
--- The current microcode level for 220742(hfcldd0)
--- Select microcode file: /home/okamoto/54100A30.220742.EF.500008700030F17A.BK
File WWN=50000870 0030F17A
Target WWN=50000870 0030F1B6
Input data error.(WWN is wrong)
>>>>>>>>>>>>>>> hfcldd1
hfcldd1 HITACHI FC Adapter
*** NOTICE *** NOTICE *** NOTICE ***
~~~
Omission
~~~
Microcode Update finished.
The Update microcode level for 220742(hfcldd1)
Need reboot the system to update this.
>>>>>>>>>>>>>>> hfcldd2 SKIP(already update)
<Result of all adapter update>
Adapter #1: FAIL (FlASH SYSREV 00220740)
hfcldd0: FAIL
Adapter #2: SUCCESS (FLASH SYSREV 00220740 -> 00220742)
hfcldd1: SUCCESS
hfcldd2: SKIP
#
Update failed because the specified backup file and
WWPN of the adapter port does not match
‘hfcldd2’ belongs to the same board as hfcldd1.
FLASH-ROM data has already updated as
‘hfcldd1’, so update is skipped for hfcldd2.
Display the result at the end of the command.